Product filter

  • Function
    • Fiber Optic
    Gateways
    Converter
    Divider & Multiplier
    Splitter
  • Input format
    Input format
    Number of inputs
  • Outputs
    Number of outputs
    Outputs
  • Interface
    Interface
  • Supply voltage
    Supply voltage
  • Housing
    Housing

Fiber Optic

Products found: 53

The innovative optical fiber modules from motrona ensure reliable transmission of encoder signals over distances of up to 3000 m. They are resistant to extremely strong electromagnetic fields and disturbances. Thus, our fiber optic modules are predestined for use in potentially explosive atmospheres.

EG220

Smart Edge Gateway

Signalformat: Analog (V, mA)
Signalformat Ausgang: 4 Transistoren
  • 4 analog inputs 15 bits for ±10 V or 0/4 ... 20 mA
  • 16 digital inputs for HTL, PNP signals [10 ... 30 VDC]
  • 4 digital outputs for PNP signals [5 ... 30 V]
  • Power supply 18 ... 30 VDC
  • Ethernet port RJ45 interface for MQTT protocol
  • 4 USB interfaces
  • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
  • Flexible connection of various sensor signals and secure transmission of data to the cloud via TLS protocol
  • MQTTS container as data layer
  • Options for up to 3 pluggable EM220 extension modules
  • Automatic hardware detection and dynamic adaptation of web backend and frontend
  • The firmware and device parameters are protected by a multi-level security procedure and dongle
  • Visualization and configuration via sens2cloud web application
  • Various data packages available
  • Cloud: Hosted in the EU for maximum security and availability
  • Data is securely protected against unauthorized access by two-factor authentication
  • Company and user profiles and their permissions can be freely configured – CI also taken into account
  • Analysis of data via customizable dashboards
  • Parameterization of devices
  • Management and parameterization of all registered devices
  • API interface for easy integration into existing third-party applications
     

PN220

PROFINET Fieldbus Coupler

Signalformat: Analog (V, mA)
Signalformat Ausgang: 8 Transistoren
Schnittstellen: PROFINET
  • 4 analog inputs 15 bit for ±10 V or 0/4 ... 20 mA
  • 12 digital inputs for HTL, PNP signals [10 ... 30 VDC]
  • 8 digital outputs for PNP signals [5 ... 30 V]
  • Power supply 18 ... 30 VDC
  • PROFINET IO Device Conformance Class B
  • Dual Port Ethernet with integrated switch
  • Extendable with various extension modules
  • Device configuration possible via engineering tools and PLC controllers from various manufacturers
     
SinCos Interpolator with Incremental Output (HTL / RS422)

SI220

SinCos Interpolator with Incremental Output (HTL / RS422)

Signalformat: SinCos (1 Vss)
Signalformat Ausgang: Impuls (HTL, TTL)
Signalformat Ausgang: Frequenz (HTL, TTL)
  • Encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
  • Control input „Error Release“ for PNP signals [10 ... 30 VDC]
  • Input frequency up to 400 kHz
  • Pulse output with format A, /A, B, /B, Z, /Z [RS422] or with format A, B, 90° [HTL]
  • Output frequency up to 4 MHz [RS422]
  • Control output „Error“ with push-pull characteristic,
    short-circuit-proof, [5 ... 30 VDC]
  • Power supply 18 ... 30 VDC
  • Snap-on housing for top hat rail (according to EN 60715)
  • Adjustable multiplier for interpolation rates from 1:5 to 1:50
  • Adjustable divider 1:1 – 1:255 to reduce the output frequency
Signal Converter SSI >>> IO-Link

IO223

Signal Converter SSI >>> IO-Link

Signalformat: SSI (DATA, CLOCK)
Schnittstellen: IO-Link
  • 1 SSI input (10 … 32 bit)
  • for singleturn and multiturn encoders
  • optionally 3 control inputs for PNP signals [10 ... 30 VDC]
  • IO link interface
  • Power supply 12 ... 30 VDC
  • Compact housing for mounting on 35 mm DIN rail
    (according to EN 60715)
Signal Converter Incremental >>> IO-Link

IO222

Signal Converter Incremental >>> IO-Link

Signalformat: Frequenz (HTL, TTL)
Schnittstellen: IO-Link
  • 1 incremental input (A, /A, B, /B)
  • for HTL/TTL/RS422 for NPN/PNP/NAMUR encoders and sensors
  • optionally 3 control inputs for PNP signals [10 ... 30 VDC]
  • IO link interface
  • Power supply 12 ... 30 VDC
  • Compact housing for mounting on 35 mm DIN rail
    (according to EN 60715)
Signal Converter Strain gauge >>> IO-Link

IO221

Signal Converter Strain gauge >>> IO-Link

Signalformat: DMS (mV/V)
Schnittstellen: IO-Link
  • 1 Strain gauge input
  • 3 VDC and 10 VDC bridge voltage per sensor connection
  • 1 … 10 mV sensitivity
  • optionally 3 control inputs for PNP signals [10 ... 30 VDC]
  • IO link interface
  • Power supply 12 ... 30 VDC
  • Compact housing for mounting on 35 mm DIN rail
    (according to EN 60715)

IO220

Signal Converter Analog >>> IO-Link

Signalformat: Analog (V, mA)
Schnittstellen: IO-Link
  • 4 analog inputs for ±10 V or 0/4 ... 20 mA (2x current / 2x voltage)
  • optionally 3 control inputs for PNP signals [10 ... 30 VDC]
  • IO link interface
  • Power supply 12 ... 30 VDC
  • Compact housing for mounting on 35 mm DIN rail
    (according to EN 60715)
2 channel Strain Gauge Amplifier >>> Analog

DM222

2 channel Strain Gauge Amplifier >>> Analog

Signalformat: DMS (mV/V)
Signalformat Ausgang: Analog (V, mA)
  • 6-wire connection for two independent strain gauge full bridge sensors
  • 4 control inputs [HTL/PNP]
  • 2 independent analog outputs ±10 V, 0/4 ... 20 mA, 16 bit
  • 4 control outputs for signaling different operation states
  • Power supply 18 ... 30 VDC
  • Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
  • Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
  • Sensitivity of the sensor inputs 1 ... 10 mV
  • Transmission of the sensor data via RS485
  • Programming via USB and the user interface OS (freeware)
  • Protection class IP20
  • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
Strain Gauge Amplifier >>> Analog

DM221

Strain Gauge Amplifier >>> Analog

Signalformat: DMS (mV/V)
Signalformat Ausgang: Analog (V, mA)
  • 6-wire connection for one strain gauge full bridge sensor
  • 4 control inputs [HTL/PNP]
  • 1 analog output ±10 V, 0/4 ... 20 mA, 16 bit
  • 4 control outputs for signaling different operation states
  • Power supply 18 ... 30 VDC
  • Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
  • Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
  • Sensitivity of the sensor inputs 1 ... 10 mV
  • Transmission of the sensor data via RS485
  • Programming via USB and the user interface OS (freeware)
  • Protection class IP20
  • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
Signal Distributor for Incremental Encoder without Potential Separation, 4 Outputs

GV224

Impulse Distributor for Incremental Encoder without Potential Separation, 4 Outputs

Signalformat: Frequenz (HTL, TTL)
Signalformat: Impuls (HTL, TTL)
Signalformat Ausgang: Frequenz (HTL, TTL)
Signalformat Ausgang: Impuls (HTL, TTL)
  • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422 / HTL differential]
  • Input frequency up to 350 kHz [SE TTL / SE HTL]  or 1 MHz [RS422 / HTL differential]
  • 4 pulse outputs, formats corresponds to those of the input signals, but with individual assignment of the output level for each output
  • BUS interface for quick and easy expansion of the number of outputs
  • Power supply 10 ... 30 VDC
  • Signal delay time 430 ns
  • Input level at RS422 / TTL (differential voltage > 0.5 V),
  • Input level at HTL differential (differential voltage > 2 V),
  • Input level at HTL asymmetric LOW: 0 ... 5 V HIGH: 9 ... 30 V
  • Input level at TTL (asymmetrical): LOW: 0 ... 0.6 V HIGH: 2.2 ... 5 V
  • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
  • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")