Products found: 53
EG220
Smart Edge Gateway
- 4 analog inputs 15 bits for ±10 V or 0/4 ... 20 mA
- 16 digital inputs for HTL, PNP signals [10 ... 30 VDC]
- 4 digital outputs for PNP signals [5 ... 30 V]
- Power supply 18 ... 30 VDC
- Ethernet port RJ45 interface for MQTT protocol
- 4 USB interfaces
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
- Flexible connection of various sensor signals and secure transmission of data to the cloud via TLS protocol
- MQTTS container as data layer
- Options for up to 3 pluggable EM220 extension modules
- Automatic hardware detection and dynamic adaptation of web backend and frontend
- The firmware and device parameters are protected by a multi-level security procedure and dongle
- Visualization and configuration via sens2cloud web application
- Various data packages available
- Cloud: Hosted in the EU for maximum security and availability
- Data is securely protected against unauthorized access by two-factor authentication
- Company and user profiles and their permissions can be freely configured – CI also taken into account
- Analysis of data via customizable dashboards
- Parameterization of devices
- Management and parameterization of all registered devices
- API interface for easy integration into existing third-party applications
PN220
PROFINET Fieldbus Coupler
- 4 analog inputs 15 bit for ±10 V or 0/4 ... 20 mA
- 12 digital inputs for HTL, PNP signals [10 ... 30 VDC]
- 8 digital outputs for PNP signals [5 ... 30 V]
- Power supply 18 ... 30 VDC
- PROFINET IO Device Conformance Class B
- Dual Port Ethernet with integrated switch
- Extendable with various extension modules
- Device configuration possible via engineering tools and PLC controllers from various manufacturers
SI220
SinCos Interpolator with Incremental Output (HTL / RS422)
- Encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
- Control input „Error Release“ for PNP signals [10 ... 30 VDC]
- Input frequency up to 400 kHz
- Pulse output with format A, /A, B, /B, Z, /Z [RS422] or with format A, B, 90° [HTL]
- Output frequency up to 4 MHz [RS422]
- Control output „Error“ with push-pull characteristic,
short-circuit-proof, [5 ... 30 VDC] - Power supply 18 ... 30 VDC
- Snap-on housing for top hat rail (according to EN 60715)
- Adjustable multiplier for interpolation rates from 1:5 to 1:50
- Adjustable divider 1:1 – 1:255 to reduce the output frequency
IO223
Signal Converter SSI >>> IO-Link
- 1 SSI input (10 … 32 bit)
- for singleturn and multiturn encoders
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
- Power supply 12 ... 30 VDC
- Compact housing for mounting on 35 mm DIN rail
(according to EN 60715)
IO222
Signal Converter Incremental >>> IO-Link
- 1 incremental input (A, /A, B, /B)
- for HTL/TTL/RS422 for NPN/PNP/NAMUR encoders and sensors
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
- Power supply 12 ... 30 VDC
- Compact housing for mounting on 35 mm DIN rail
(according to EN 60715)
IO221
Signal Converter Strain gauge >>> IO-Link
- 1 Strain gauge input
- 3 VDC and 10 VDC bridge voltage per sensor connection
- 1 … 10 mV sensitivity
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
- Power supply 12 ... 30 VDC
- Compact housing for mounting on 35 mm DIN rail
(according to EN 60715)
IO220
Signal Converter Analog >>> IO-Link
- 4 analog inputs for ±10 V or 0/4 ... 20 mA (2x current / 2x voltage)
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
- Power supply 12 ... 30 VDC
- Compact housing for mounting on 35 mm DIN rail
(according to EN 60715)
DM222
2 channel Strain Gauge Amplifier >>> Analog
- 6-wire connection for two independent strain gauge full bridge sensors
- 4 control inputs [HTL/PNP]
- 2 independent analog outputs ±10 V, 0/4 ... 20 mA, 16 bit
- 4 control outputs for signaling different operation states
- Power supply 18 ... 30 VDC
- Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
- Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
- Sensitivity of the sensor inputs 1 ... 10 mV
- Transmission of the sensor data via RS485
- Programming via USB and the user interface OS (freeware)
- Protection class IP20
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
DM221
Strain Gauge Amplifier >>> Analog
- 6-wire connection for one strain gauge full bridge sensor
- 4 control inputs [HTL/PNP]
- 1 analog output ±10 V, 0/4 ... 20 mA, 16 bit
- 4 control outputs for signaling different operation states
- Power supply 18 ... 30 VDC
- Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
- Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
- Sensitivity of the sensor inputs 1 ... 10 mV
- Transmission of the sensor data via RS485
- Programming via USB and the user interface OS (freeware)
- Protection class IP20
- Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
GV224
Impulse Distributor for Incremental Encoder without Potential Separation, 4 Outputs
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422 / HTL differential]
- Input frequency up to 350 kHz [SE TTL / SE HTL] or 1 MHz [RS422 / HTL differential]
- 4 pulse outputs, formats corresponds to those of the input signals, but with individual assignment of the output level for each output
- BUS interface for quick and easy expansion of the number of outputs
- Power supply 10 ... 30 VDC
- Signal delay time 430 ns
- Input level at RS422 / TTL (differential voltage > 0.5 V),
- Input level at HTL differential (differential voltage > 2 V),
- Input level at HTL asymmetric LOW: 0 ... 5 V HIGH: 9 ... 30 V
- Input level at TTL (asymmetrical): LOW: 0 ... 0.6 V HIGH: 2.2 ... 5 V
- Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
- Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")