Product filter

  • Function
    Gateways
    Converter
      Divider & Multiplier
        Splitter
        • Input format
          Input format
          Number of inputs
        • Outputs
          Number of outputs
            Outputs
            • Interface
              Interface
              • Supply voltage
                Supply voltage
                • Housing
                  Housing
                  Products found: 47

                  EG222

                  Smart Edge Gateway

                  Signalformat: Analog (V, mA)
                  Signalformat Ausgang: 4 Transistoren
                  • 4 analog inputs 15 bits for ±10 V or 0/4 ... 20 mA
                  • 16 digital inputs for HTL, PNP signals [10 ... 30 VDC]
                  • 4 digital outputs for PNP signals [5 ... 30 V]
                  • Power supply 18 ... 30 VDC
                  • Ethernet port RJ45 interface for MQTTS protocol
                  • 4 USB interfaces
                  • RS232 to RS485 adapter for Modbus communication
                  • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
                  • Flexible connection of various sensor signals and secure transmission of data to the cloud via TLS protocol
                  • MQTTS container as data layer
                  • Options for up to 3 pluggable EM222 extension modules
                  • Automatic hardware detection and dynamic adaptation of web backend and frontend
                  • The firmware and device parameters are protected by a multi-level security procedure and dongle
                  • Visualization and configuration via sens2cloud web application
                  • Various data packages available
                  • Cloud: Hosted in the EU for maximum security and availability
                  • Data is securely protected against unauthorized access by two-factor authentication
                  • Company and user profiles and their permissions can be freely configured – CI also taken into account
                  • Analysis of data via customizable dashboards
                  • Parameterization of devices
                  • Management and parameterization of all registered devices
                  • API interface for easy integration into existing third-party applications
                     

                  PN222

                  PROFINET Fieldbus Coupler

                  Signalformat: Analog (V, mA)
                  Signalformat Ausgang: 8 Transistoren
                  Schnittstellen: PROFINET
                  • 4 analog inputs 15 bit for ±10 V or 0/4 ... 20 mA
                  • 12 digital inputs for HTL, PNP signals [10 ... 30 VDC]
                  • 8 digital outputs for PNP signals [5 ... 30 V]
                  • Power supply 18 ... 30 VDC
                  • PROFINET IO Device Conformance Class B
                  • Dual Port Ethernet with integrated switch
                  • RS232 to RS485 Adapter for Modbus Communication
                  • Extendable with various extension modules
                  • Device configuration possible via engineering tools and PLC controllers from various manufacturers
                     
                  SinCos Interpolator with Incremental Output (HTL / RS422)

                  SI220

                  SinCos Interpolator with Incremental Output (HTL / RS422)

                  Signalformat: SinCos (1 Vss)
                  Signalformat Ausgang: Impuls (HTL, TTL)
                  Signalformat Ausgang: Frequenz (HTL, TTL)
                  • Encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
                  • Control input „Error Release“ for PNP signals [10 ... 30 VDC]
                  • Input frequency up to 400 kHz
                  • Pulse output with format A, /A, B, /B, Z, /Z [RS422] or with format A, B, 90° [HTL]
                  • Output frequency up to 4 MHz [RS422]
                  • Control output „Error“ with push-pull characteristic,
                    short-circuit-proof, [5 ... 30 VDC]
                  • Power supply 18 ... 30 VDC
                  • Snap-on housing for top hat rail (according to EN 60715)
                  • Adjustable multiplier for interpolation rates from 1:5 to 1:50
                  • Adjustable divider 1:1 – 1:255 to reduce the output frequency
                  Signal Converter SSI >>> IO-Link

                  IO223

                  Signal Converter SSI >>> IO-Link

                  Signalformat: SSI (DATA, CLOCK)
                  Schnittstellen: IO-Link
                  • 1 SSI input (10 … 32 bit)
                  • for singleturn and multiturn encoders
                  • optionally 3 control inputs for PNP signals [10 ... 30 VDC]
                  • IO link interface
                  • Power supply 12 ... 30 VDC
                  • Compact housing for mounting on 35 mm DIN rail
                    (according to EN 60715)
                  Signal Converter Incremental >>> IO-Link

                  IO222

                  Signal Converter Incremental >>> IO-Link

                  Signalformat: Frequenz (HTL, TTL)
                  Schnittstellen: IO-Link
                  • 1 incremental input (A, /A, B, /B)
                  • for HTL/TTL/RS422 for NPN/PNP/NAMUR encoders and sensors
                  • optionally 3 control inputs for PNP signals [10 ... 30 VDC]
                  • IO link interface
                  • Power supply 12 ... 30 VDC
                  • Compact housing for mounting on 35 mm DIN rail
                    (according to EN 60715)
                  Signal Converter Strain gauge >>> IO-Link

                  IO221

                  Signal Converter Strain gauge >>> IO-Link

                  Signalformat: DMS (mV/V)
                  Schnittstellen: IO-Link
                  • 1 Strain gauge input
                  • 3 VDC and 10 VDC bridge voltage per sensor connection
                  • 1 … 10 mV sensitivity
                  • optionally 3 control inputs for PNP signals [10 ... 30 VDC]
                  • IO link interface
                  • Power supply 12 ... 30 VDC
                  • Compact housing for mounting on 35 mm DIN rail
                    (according to EN 60715)

                  IO220

                  Signal Converter Analog >>> IO-Link

                  Signalformat: Analog (V, mA)
                  Schnittstellen: IO-Link
                  • 4 analog inputs for ±10 V or 0/4 ... 20 mA (2x current / 2x voltage)
                  • optionally 3 control inputs for PNP signals [10 ... 30 VDC]
                  • IO link interface
                  • Power supply 12 ... 30 VDC
                  • Compact housing for mounting on 35 mm DIN rail
                    (according to EN 60715)
                  2 channel Strain Gauge Amplifier >>> Analog

                  DM222

                  2 channel Strain Gauge Amplifier >>> Analog

                  Signalformat: DMS (mV/V)
                  Signalformat Ausgang: Analog (V, mA)
                  • 6-wire connection for two independent strain gauge full bridge sensors
                  • 4 control inputs [HTL/PNP]
                  • 2 independent analog outputs ±10 V, 0/4 ... 20 mA, 16 bit
                  • 4 control outputs for signaling different operation states
                  • Power supply 18 ... 30 VDC
                  • Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
                  • Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
                  • Sensitivity of the sensor inputs 1 ... 10 mV
                  • Transmission of the sensor data via RS485
                  • Programming via USB and the user interface OS (freeware)
                  • Protection class IP20
                  • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
                  Strain Gauge Amplifier >>> Analog

                  DM221

                  Strain Gauge Amplifier >>> Analog

                  Signalformat: DMS (mV/V)
                  Signalformat Ausgang: Analog (V, mA)
                  • 6-wire connection for one strain gauge full bridge sensor
                  • 4 control inputs [HTL/PNP]
                  • 1 analog output ±10 V, 0/4 ... 20 mA, 16 bit
                  • 4 control outputs for signaling different operation states
                  • Power supply 18 ... 30 VDC
                  • Functions for scaling and linking the sensor signals (e.g. A+B, A-B, ...)
                  • Adjustable bridge voltage per sensor from 3 VDC ... 10 VDC
                  • Sensitivity of the sensor inputs 1 ... 10 mV
                  • Transmission of the sensor data via RS485
                  • Programming via USB and the user interface OS (freeware)
                  • Protection class IP20
                  • Compact housing for mounting on 35 mm top-hat rail (according to EN 60715)
                  Signal Distributor for Incremental Encoder without Potential Separation, 4 Outputs

                  GV224

                  Impulse Distributor for Incremental Encoder without Potential Separation, 4 Outputs

                  Signalformat: Frequenz (HTL, TTL)
                  Signalformat: Impuls (HTL, TTL)
                  Signalformat Ausgang: Frequenz (HTL, TTL)
                  Signalformat Ausgang: Impuls (HTL, TTL)
                  • 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422 / HTL differential]
                  • Input frequency up to 350 kHz [SE TTL / SE HTL]  or 1 MHz [RS422 / HTL differential]
                  • 4 pulse outputs, formats corresponds to those of the input signals, but with individual assignment of the output level for each output
                  • BUS interface for quick and easy expansion of the number of outputs
                  • Power supply 10 ... 30 VDC
                  • Signal delay time 430 ns
                  • Input level at RS422 / TTL (differential voltage > 0.5 V),
                  • Input level at HTL differential (differential voltage > 2 V),
                  • Input level at HTL asymmetric LOW: 0 ... 5 V HIGH: 9 ... 30 V
                  • Input level at TTL (asymmetrical): LOW: 0 ... 0.6 V HIGH: 2.2 ... 5 V
                  • Compact housing for mounting on 35 mm top hat rail (according to EN 60715)
                  • Dimensions W x H x D = 34 x 118 x 140 mm (1,34 x 4,65 x 5,51")