Product filter

  • Function
    Analog Value Indicator
      Incremental Indicator
        Position Indicator
          Process Value Indicator
          • Input format
            Input format
              Number of inputs
              • Outputs
                Outputs
                • Preselection
                  Preselection
                  • Display
                    Display
                    • Interface
                      Interface
                      • Supply voltage
                        Supply voltage
                        • Housing
                          Housing
                          Products found: 16
                          touchMATRIX® EtherCAT Indicator

                          EC350

                          touchMATRIX® EtherCAT Indicator

                          Schnittstellen: EtherCAT
                          • EtherCAT interface
                          • 5 control inputs for remote release
                          • Power supply 18 ... 30 VDC
                          • Norm panel housing with 96 x 48 mm and protection class IP65
                          • Bright and high-contrast graphic display with event-dependent color variants
                          • Emulation of a 7-segment display with symbols, units and bargraph
                          • Intuitive and simple parameterization through plain text and touchscreen
                          touchMATRIX® Profinet Indicator

                          PN350

                          touchMATRIX® PROFINET Indicator

                          Schnittstellen: PROFINET
                          • PROFINET interface
                          • 5 control inputs for remote release
                          • Power supply 18 ... 30 VDC
                          • Norm panel housing with 96 x 48 mm and protection class IP65
                          • Bright and high-contrast graphic display with event-dependent color variants
                          • Emulation of a 7-segment display with symbols and units
                          • Intuitive and simple parameterization through plain text and touchscreen
                          touchMATRIX® Strain Gauge Indicator for force sensors (full bridge)

                          DM350

                          touchMATRIX® Strain Gauge Indicator for force sensors (full bridge)

                          Signalformat: DMS (mV/V)
                          • Strain gauge input, 6-wire connection
                          • 3 control inputs for HTL / PNP signals
                          • Power supply 18 ... 30 VDC
                          • Adjustable bridge voltage 3 VDC to 10 VDC
                          • 1 … 10 mV sensitivity
                          • Standard installation housing with 96 x 48 mm and protection class IP65
                          • Bright and high-contrast graphic display with event-dependent color variants
                          • Emulation of a 7-segment display with symbols and units
                          • Intuitive and simple parameterization through plain text and touchscreen
                          • Numerous functions such as tare, filter, averaging
                          • Linearization with 24 support points
                          • Option AC: Power supply 115 ... 230 VAC
                          • Option AO: 16 bit analog output, 4 control outputs, serial RS232 interface
                          • Option AR: 16 bit analog output, 4 control outputs, serial RS485 interface
                          • Option CO: 4 control outputs, serial RS232 interface
                          • Option CR: 4 control outputs, serial RS485 interface
                          • Option RL: 2 relay outputs
                          • Option IO: IO-Link Device V1.1

                          Options can be combined.

                          Process Indicator with two 16 bit Analog Inputs

                          AX350

                          touchMATRIX® Process Indicator with two 16 bit Analog Inputs

                          Signalformat: Analog (V, mA)
                          • 2 universal 16 bit analogue inputs for ±10 V or 0/4 … 20 mA
                          • 3 control inputs for HTL / PNP signals
                          • Power supply 18 ... 30 VDC
                          • 24 V auxiliary output for encoder supply
                          • High accuracy reference output 10 V for
                            potentiometers > 1 kOhm
                          • 3.78 x 1.89 inch norm panel housing and IP65 protection
                          • Bright and high-contrast display with event-dependent color variations
                          • Emulation of a 7-segment display inclusively icons and units
                          • Intuitive and easy parameterization by plain text and touchscreen
                          • Operating modes for visualization of INPUT 1, INPUT 2 or
                            combinations of IN1 + IN2, IN1 - IN2, IN1 x IN2, IN1: IN2
                          • Numerous features, e. g. tara, filters, averaging
                          • Linearization with 24 control points
                          • Option AC: Power supply 115 ... 230 VAC
                          • Option AO: 16 bit analog output, 4 control outputs,
                            serial RS232 interface
                          • Option AR: 16 bit analog output, 4 control outputs,
                            serial RS485 interface
                          • Option CO: 4 control outputs, serial RS232 interface
                          • Option CR: 4 control outputs, serial RS485 interface
                          • Option RL: 2 relay outputs
                          • Option IO: IO-Link Device V1.1

                            Options can be combined.
                          touchMATRIX® IO-Link Indicator

                          AX350/IO

                          touchMATRIX® IO-Link Indicator

                          Signalformat: Analog (V, mA)
                          Schnittstellen: IO-Link
                          • 2 universal 16 bit analog inputs for ±10 V or 0/4 … 20 mA
                          • 3 control inputs for HTL / PNP signals
                          • Power supply 18 ... 30 VDC
                          • 24 V auxiliary output for encoder supply
                          • High accuracy reference output 10 V for 
                            potentiometers > 1 kOhm
                          • 3.78 x 1.89 inch norm panel housing and IP65 protection
                          • Bright and high-contrast display with event-dependent color variations
                          • Emulation of a 7-segment display inclusively icons and units
                          • Intuitive and easy parameterization by plain text and touchscreen
                          • Operating modes for visualization of INPUT 1, INPUT 2 or
                            combinations of IN1 + IN2, IN1 - IN2, IN1 x IN2, IN1: IN2
                          • Numerous features, e. g. Ttara, filters, averaging
                          • Linearization with 24 control points

                          Option IO (= IO-Link Device)

                          • Data transfer via COM3 (230,4 kBaud)
                          • Cycle times < 3 msec
                          • Process data IN 32 Byte (6 x process values from AX350):
                            - Analog value 1 (scaled / linearized) and unit
                            - Analog value 2 (scaled / linearized) and unit
                            - Analog value 1 (scaled / linearized) with totalisation and unit
                            - Analog value 2 (scaled / linearized) with totalisation and unit
                            - Shortcut analog value 1 (scaled / linearized) with analog value 2  (scaled / linearized) and unit
                            - Shortcut totalisator analog value 1 (scaled / linearized) with totalisator analog value 2 (scaled / linearized) and unit
                          • Process data Out 8 Byte (2 x IO-Link process values to AX350):
                            - IOL process value Out 1 with scaling, adjustable decimal point and programmable units
                            - IOL process values Out 2 with scaling, adjustable decimal point and programmable units

                          Combinable with further options:

                          • Option AC: Power supply 115 ... 230 VAC
                          • Option AO: 16 bit analog output, 4 control outputs,
                            serial RS232 interface
                          • Option AR: 16 bit analog output, 4 control outputs,
                            serial RS485 interface
                          • Option CO: 4 control outputs, serial RS232 interface
                          • Option CR: 4 control outputs, serial RS485 interface
                          • Option RL: 2 relay outputs
                          touchMATRIX® Digital Indicator (HTL)

                          DX350

                          touchMATRIX® Digital Indicator (HTL)

                          Signalformat: Impuls (HTL, TTL)
                          Signalformat: Frequenz (HTL, TTL)
                          • Pulse input with format A, B, 90° [HTL], single channel as an option
                          • HTL inputs for encoder and sensors with NPN / PNP or NAMUR switching characteristics
                          • Input frequency up to 250 kHz
                          • 3 control inputs for HTL / PNP signals
                          • Power supply 18 ... 30 VDC
                          • 24 V auxiliary output for encoder supply
                          • 3.78 x 1.89 inch norm panel housing and IP65 protection
                          • Bright and high-contrast display with event-dependent color variations
                          • Emulation of a 7-segment display inclusively icons and units
                          • Intuitive and easy parameterization by plain text and touchscreen
                          • Multi functional device for speed, position, timer, counter or velocity application
                          • Operating modes such as scaling, average filter, start up suppression
                          • Linearization with 24 control points
                          • Option AC: Power supply 115 ... 230 VAC
                          • Option AO: 16 bit analog output, 4 control outputs, serial RS232 interface
                          • Option AR: 16 bit analog output, 4 control outputs,serial RS485 interface
                          • Option CO: 4 control outputs, serial RS232 interface
                          • Option CR: 4 control outputs, serial RS485 interface
                          • Option RL: 2 relay outputs

                          Options can be combined.

                          touchMATRIX® Graphic Display (HTL / RS422)

                          DX355

                          touchMATRIX® Graphic Display (HTL / RS422)

                          Signalformat: Impuls (HTL, TTL)
                          Signalformat: Frequenz (HTL, TTL)
                          • 2 Incremental inputs with format A, /A, B, /B
                          • Differential, single-ended HTL / RS422
                          • Input frequency up to 1 MHz
                          • Power supply 18 ... 30 VDC
                          • 5 / 24 VDC auxiliary output for encoder supply
                          • 3.78 x 1.89 inch norm panel housing and IP65 protection
                          • Bright and high-contrast display with event-dependent color variations
                          • Emulation of a 7-segment display inclusively icons and units
                          • Intuitive and easy parameterization by plain text and touchscreen
                          • Multi functional device for speed, process time, timer, counter or velocity application
                          • Operating modes such as scaling, average filter, start up suppression
                          • Linearization with 24 control points
                             
                          • Option AC: Power supply 115 ... 230 VAC
                          • Option AO: 16 bit analog output, 4 control outputs,
                            serial RS232 interface
                          • Option AR: 16 bit analog output, 4 control outputs,
                            serial RS485 interface
                          • Option CO: 4 control outputs, serial RS232 interface
                          • Option CR: 4 control outputs, serial RS485 interface
                          • Option RL: 2 relay outputs

                            Options can be combined.
                          touchMATRIX® Combi Indicator

                          MX350

                          touchMATRIX® Combi Indicator Speed / Length

                          Signalformat: Impuls (HTL, TTL)
                          Signalformat: Frequenz (HTL, TTL)
                          • Pulse input with format A, B, 90° [HTL], single channel as an option
                          • HTL input for encoder and sensors with NPN / PNP or NAMUR switching characteristics
                          • Input frequency up to 250 kHz
                          • 3 control inputs for HTL / PNP signals
                          • Power supply 18 ... 30 VDC
                          • 24 V auxiliary output for encoder supply
                          • 3.78 x 1.89 inch norm panel housing and IP65 protection
                          • Bright and high-contrast display with event-dependent colour variations
                          • Emulation of a 7-segment display inclusively icons and units
                          • Intuitive and easy parameterization by plain text and touchscreen
                          • Multi-function device for use as speedometer / tachometer, pulse counter / position indicator, number counter and total counter
                          • Operating modes such as scaling, average filter, start up suppression
                          • Linearization with 24 control points
                             
                          • Option AC: Power supply 115 ... 230 VAC
                          • Option AO: 16 bit analog output, 4 control outputs, serial RS232 interface
                          • Option AR: 16 bit analog output, 4 control outputs, serial RS485 interface
                          • Option CO: 4 control outputs, serial RS232 interface
                          • Option CR: 4 control outputs, serial RS485 interface
                          • Option RL: 2 relay outputs

                          Options can be combined.

                          touchMATRIX® tachometer with dual evaluation (HTL)

                          MX355

                          touchMATRIX® Combi Indicator Speed / Length

                          Signalformat: Impuls (HTL, TTL)
                          Signalformat: Frequenz (HTL, TTL)
                          • Incremental input with format A, /A, B, /B
                          • Differential, single-ended HTL / RS422
                          • Input frequency up to 1 MHz
                          • 3 control inputs for HTL / PNP signals
                          • Power supply 18 ... 30 VDC
                          • 24 V auxiliary output for encoder supply
                          • 3.78 x 1.89 inch norm panel housing and IP65 protection
                          • Bright and high-contrast display with event-dependent colour variations
                          • Emulation of a 7-segment display inclusively icons and units
                          • Intuitive and easy parameterization by plain text and touchscreen
                          • Multi-function device for use as speedometer / tachometer, pulse counter / position indicator, number counter and total counter
                          • Operating modes such as scaling, average filter, start up suppression
                          • Linearization with 24 control points
                             
                          • Option AC: Power supply 115 ... 230 VAC
                          • Option AO: 16 bit analog output, 4 control outputs, serial RS232 interface
                          • Option AR: 16 bit analog output, 4 control outputs, serial RS485 interface
                          • Option CO: 4 control outputs, serial RS232 interface
                          • Option CR: 4 control outputs, serial RS485 interface
                          • Option RL: 2 relay outputs

                          Options can be combined.

                          touchMATRIX® Combi Indicator Absolute Position / Speed

                          IX350

                          touchMATRIX® Combi Indicator Absolute Position / Speed

                          Signalformat: SSI (DATA, CLOCK)
                          • SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
                          • SSI clock frequencies up to 1 MHz
                          • Master or Slave operation
                          • For single turn and multi turn encoders with 10 … 32 Bit
                          • 3 control inputs for HTL / PNP signals
                          • Power supply 18 ... 30 VDC
                          • 24 V auxiliary output for encoder supply
                          • 3.78 x 1.89 inch norm panel housing and IP65 protection
                          • Bright and high-contrast display with event-dependent color variations
                          • Emulation of a 7-segment display inclusively icons and units
                          • Intuitive and easy parameterization by plain text and touchscreen
                          • Operating modes such as scaling and bit blanking
                          • Linearization with 24 control points
                             
                          • Option AC: Power supply 115 ... 230 VAC
                          • Option AO: 16 bit analog output, 4 control outputs,
                            serial RS232 interface
                          • Option AR: 16 bit analog output, 4 control outputs,
                            serial RS485 interface
                          • Option CO: 4 control outputs, serial RS232 interface
                          • Option CR: 4 control outputs, serial RS485 interface
                          • Option RL: 2 relay outputs

                            Options can be combined.