Product filter

  • Function
    Analog Value Indicator
    Incremental Indicator
    Position Indicator
    Process Value Indicator
  • Input format
    Input format
    Number of inputs
  • Outputs
    Outputs
  • Preselection
    Preselection
  • Display
    Display
  • Interface
    Interface
  • Supply voltage
    Supply voltage
  • Housing
    Housing
Products found: 59
touchMATRIX® EtherNET/IP Indicator

EN350

touchMATRIX® EtherNET/IP Indicator

Interface: Ethernet / IP
  • EtherNET/IP interface
  • 3 control inputs for remote release
  • Power supply 18 ... 30 VDC
  • Norm panel housing with 96 x 48 mm and protection class IP65
  • Bright and high-contrast graphic display with event-dependent color variants
  • Emulation of a 7-segment display with symbols, units and bargraph
  • Intuitive and simple parameterization through plain text and touchscreen
touchMATRIX® EtherCAT Indicator

EC350

touchMATRIX® EtherCAT Indicator

Interface: EtherCAT
  • EtherCAT interface
  • 3 control inputs for remote release
  • Power supply 18 ... 30 VDC
  • Norm panel housing with 96 x 48 mm and protection class IP65
  • Bright and high-contrast graphic display with event-dependent color variants
  • Emulation of a 7-segment display with symbols, units and bargraph
  • Intuitive and simple parameterization through plain text and touchscreen
touchMATRIX® Profinet Indicator

PN350

touchMATRIX® PROFINET Indicator

Interface: PROFINET
  • PROFINET interface
  • 3 control inputs for remote release
  • Power supply 18 ... 30 VDC
  • Norm panel housing with 96 x 48 mm and protection class IP65
  • Bright and high-contrast graphic display with event-dependent color variants
  • Emulation of a 7-segment display with symbols and units
  • Intuitive and simple parameterization through plain text and touchscreen
touchMATRIX® Strain Gauge Indicator for force sensors (full bridge)

DM350

touchMATRIX® Strain Gauge Indicator for force sensors (full bridge)

Input format: Strain Gauge (mV/V)
  • Strain gauge input, 6-wire connection
  • Input pt100 and thermocouples (J and K)
  • 3 control inputs for HTL / PNP signals
  • Power supply 18 ... 30 VDC
  • Adjustable bridge voltage 3 VDC to 10 VDC
  • 1 … 10 mV sensitivity
  • Standard installation housing with 96 x 48 mm and protection class IP65
  • Bright and high-contrast graphic display with event-dependent color variants
  • Emulation of a 7-segment display with symbols and units
  • Intuitive and simple parameterization through plain text and touchscreen
  • Numerous functions such as tare, filter, averaging
  • Linearization with 24 support points
  • Option AC: Power supply 115 ... 230 VAC
  • Option AO: 16 bit analog output, 4 control outputs, serial RS232 interface
  • Option AR: 16 bit analog output, 4 control outputs, serial RS485 interface
  • Option CO: 4 control outputs, serial RS232 interface
  • Option CR: 4 control outputs, serial RS485 interface
  • Option RL: 2 relay outputs
  • Option IO: IO-Link Device V1.1

Options can be combined.

Process Indicator with two 16 bit Analog Inputs

AX350

touchMATRIX® Process Indicator with two 16 bit Analog Inputs

Input format: Analog (V, mA)
  • 2 universal 16 bit analogue inputs for ±10 V or 0/4 … 20 mA
  • 3 control inputs for HTL / PNP signals
  • Power supply 18 ... 30 VDC
  • 24 V auxiliary output for encoder supply
  • High accuracy reference output 10 V for
    potentiometers > 1 kOhm
  • 3.78 x 1.89 inch norm panel housing and IP65 protection
  • Bright and high-contrast display with event-dependent color variations
  • Emulation of a 7-segment display inclusively icons and units
  • Intuitive and easy parameterization by plain text and touchscreen
  • Operating modes for visualization of INPUT 1, INPUT 2 or
    combinations of IN1 + IN2, IN1 - IN2, IN1 x IN2, IN1: IN2
  • Numerous features, e. g. tara, filters, averaging
  • Linearization with 24 control points
  • Option AC: Power supply 115 ... 230 VAC
  • Option AO: 16 bit analog output, 4 control outputs,
    serial RS232 interface
  • Option AR: 16 bit analog output, 4 control outputs,
    serial RS485 interface
  • Option CO: 4 control outputs, serial RS232 interface
  • Option CR: 4 control outputs, serial RS485 interface
  • Option RL: 2 relay outputs
  • Option IO: IO-Link Device V1.1

    Options can be combined.
touchMATRIX® IO-Link Indicator

AX350/IO

touchMATRIX® IO-Link Indicator

Input format: Analog (V, mA)
Interface: IO-Link
  • 2 universal 16 bit analog inputs for ±10 V or 0/4 … 20 mA
  • 3 control inputs for HTL / PNP signals
  • Power supply 18 ... 30 VDC
  • 24 V auxiliary output for encoder supply
  • High accuracy reference output 10 V for 
    potentiometers > 1 kOhm
  • 3.78 x 1.89 inch norm panel housing and IP65 protection
  • Bright and high-contrast display with event-dependent color variations
  • Emulation of a 7-segment display inclusively icons and units
  • Intuitive and easy parameterization by plain text and touchscreen
  • Operating modes for visualization of INPUT 1, INPUT 2 or
    combinations of IN1 + IN2, IN1 - IN2, IN1 x IN2, IN1: IN2
  • Numerous features, e. g. Ttara, filters, averaging
  • Linearization with 24 control points

Option IO (= IO-Link Device)

  • Data transfer via COM3 (230,4 kBaud)
  • Cycle times < 3 msec
  • Process data IN 32 Byte (6 x process values from AX350):
    - Analog value 1 (scaled / linearized) and unit
    - Analog value 2 (scaled / linearized) and unit
    - Analog value 1 (scaled / linearized) with totalisation and unit
    - Analog value 2 (scaled / linearized) with totalisation and unit
    - Shortcut analog value 1 (scaled / linearized) with analog value 2  (scaled / linearized) and unit
    - Shortcut totalisator analog value 1 (scaled / linearized) with totalisator analog value 2 (scaled / linearized) and unit
  • Process data Out 8 Byte (2 x IO-Link process values to AX350):
    - IOL process value Out 1 with scaling, adjustable decimal point and programmable units
    - IOL process values Out 2 with scaling, adjustable decimal point and programmable units

Combinable with further options:

  • Option AC: Power supply 115 ... 230 VAC
  • Option AO: 16 bit analog output, 4 control outputs,
    serial RS232 interface
  • Option AR: 16 bit analog output, 4 control outputs,
    serial RS485 interface
  • Option CO: 4 control outputs, serial RS232 interface
  • Option CR: 4 control outputs, serial RS485 interface
  • Option RL: 2 relay outputs
touchMATRIX® Digital Indicator (HTL)

DX350

touchMATRIX® Digital Indicator (HTL)

Input format: Pulse (HTL, TTL)
Input format: Frequency (HTL, TTL)
  • Pulse input with format A, B, 90° [HTL], single channel as an option
  • HTL inputs for encoder and sensors with NPN / PNP or NAMUR switching characteristics
  • Input frequency up to 250 kHz
  • 3 control inputs for HTL / PNP signals
  • Power supply 18 ... 30 VDC
  • 24 V auxiliary output for encoder supply
  • 3.78 x 1.89 inch norm panel housing and IP65 protection
  • Bright and high-contrast display with event-dependent color variations
  • Emulation of a 7-segment display inclusively icons and units
  • Intuitive and easy parameterization by plain text and touchscreen
  • Multi functional device for speed, position, timer, counter or velocity application
  • Operating modes such as scaling, average filter, start up suppression
  • Linearization with 24 control points
  • Option AC: Power supply 115 ... 230 VAC
  • Option AO: 16 bit analog output, 4 control outputs, serial RS232 interface
  • Option AR: 16 bit analog output, 4 control outputs,serial RS485 interface
  • Option CO: 4 control outputs, serial RS232 interface
  • Option CR: 4 control outputs, serial RS485 interface
  • Option RL: 2 relay outputs

Options can be combined.

touchMATRIX® Graphic Display (HTL / RS422)

DX355

touchMATRIX® Graphic Display (HTL / RS422)

Input format: Pulse (HTL, TTL)
Input format: Frequency (HTL, TTL)
  • 2 Incremental inputs with format A, /A, B, /B
  • Differential, single-ended HTL / RS422
  • Input frequency up to 1 MHz
  • Power supply 18 ... 30 VDC
  • 5 / 24 VDC auxiliary output for encoder supply
  • 3.78 x 1.89 inch norm panel housing and IP65 protection
  • Bright and high-contrast display with event-dependent color variations
  • Emulation of a 7-segment display inclusively icons and units
  • Intuitive and easy parameterization by plain text and touchscreen
  • Multi functional device for speed, process time, timer, counter or velocity application
  • Operating modes such as scaling, average filter, start up suppression
  • Linearization with 24 control points
     
  • Option AC: Power supply 115 ... 230 VAC
  • Option AO: 16 bit analog output, 4 control outputs,
    serial RS232 interface
  • Option AR: 16 bit analog output, 4 control outputs,
    serial RS485 interface
  • Option CO: 4 control outputs, serial RS232 interface
  • Option CR: 4 control outputs, serial RS485 interface
  • Option RL: 2 relay outputs

    Options can be combined.
touchMATRIX® Combi Indicator

MX350

touchMATRIX® Combi Indicator Speed / Length

Input format: Pulse (HTL, TTL)
Input format: Frequency (HTL, TTL)
  • Pulse input with format A, B, 90° [HTL], single channel as an option
  • HTL input for encoder and sensors with NPN / PNP or NAMUR switching characteristics
  • Input frequency up to 250 kHz
  • 3 control inputs for HTL / PNP signals
  • Power supply 18 ... 30 VDC
  • 24 V auxiliary output for encoder supply
  • 3.78 x 1.89 inch norm panel housing and IP65 protection
  • Bright and high-contrast display with event-dependent colour variations
  • Emulation of a 7-segment display inclusively icons and units
  • Intuitive and easy parameterization by plain text and touchscreen
  • Multi-function device for use as speedometer / tachometer, pulse counter / position indicator, number counter and total counter
  • Operating modes such as scaling, average filter, start up suppression
  • Linearization with 24 control points
     
  • Option AC: Power supply 115 ... 230 VAC
  • Option AO: 16 bit analog output, 4 control outputs, serial RS232 interface
  • Option AR: 16 bit analog output, 4 control outputs, serial RS485 interface
  • Option CO: 4 control outputs, serial RS232 interface
  • Option CR: 4 control outputs, serial RS485 interface
  • Option RL: 2 relay outputs

Options can be combined.

touchMATRIX® tachometer with dual evaluation (HTL)

MX355

touchMATRIX® Combi Indicator Speed / Length

Input format: Pulse (HTL, TTL)
Input format: Frequency (HTL, TTL)
  • Incremental input with format A, /A, B, /B
  • Differential, single-ended HTL / RS422
  • Input frequency up to 1 MHz
  • 3 control inputs for HTL / PNP signals
  • Power supply 18 ... 30 VDC
  • 24 V auxiliary output for encoder supply
  • 3.78 x 1.89 inch norm panel housing and IP65 protection
  • Bright and high-contrast display with event-dependent colour variations
  • Emulation of a 7-segment display inclusively icons and units
  • Intuitive and easy parameterization by plain text and touchscreen
  • Multi-function device for use as speedometer / tachometer, pulse counter / position indicator, number counter and total counter
  • Operating modes such as scaling, average filter, start up suppression
  • Linearization with 24 control points
     
  • Option AC: Power supply 115 ... 230 VAC
  • Option AO: 16 bit analog output, 4 control outputs, serial RS232 interface
  • Option AR: 16 bit analog output, 4 control outputs, serial RS485 interface
  • Option CO: 4 control outputs, serial RS232 interface
  • Option CR: 4 control outputs, serial RS485 interface
  • Option RL: 2 relay outputs

Options can be combined.