Often there is a high risk to people and machinery in industrial applications. In these cases, it is necessary and required by law to fulfill certain safety criteria to reduce these risks. This is precisely where the application field of our speed monitors of the DS series is. They are used to monitor underfrequencies, overfrequencies, direction of rotation and machine standstill. With their SIL3/PLe and SIL2/PLd certifications according to the DIN 61508 and ISO 13849 standards, the safety relays ensure maximum safety and reliability.

Certified Safety Monitors with SinCos Encoder without Signal Splitter

DS246

Certified Safety Monitors with SinCos Encoder without Signal Splitter

Input format: SinCos (1 Vss)
Outputs: Analog (V, mA)
Outputs: 2 Relay
Outputs: 4 Transistors
  • SIL3 and PLe certification
  • Safety functions equivalent to EN 61800-5-2
    (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
  • 1 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
  • 2 pulse inputs with format A, /A, B, /B [RS422]
  • 2 pulse- or control inputs with format A, B, 90°
    [HTL / PNP] (for rotary encoder, proximity switches or commands)
  • Input frequency up to 500 kHz
  • Forced-guided redundant output relay (NO)
  • 4 control outputs with push-pull characteristic, short-circuit-proof,
    [HTL], each inverse and redundant
  • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
  • Power supply 18 ... 30 V
  • Compact housing for 35 mm mounting top hat rail
    (according to EN 60715)
  • Setup via USB port by operator software or plug-in display and
    programming unit BG230 (accessories)
Certified Safety Monitor with Multifunctional Inputs for HTL-, RS422-, SinCos-Sensors and Signal Splitter

DS230

Certified Safety Monitor with Multifunctional Inputs for HTL-, RS422-, SinCos-Sensors and Signal Splitter

Input format: Frequency (HTL, TTL)
Input format: SinCos (1 Vss)
Outputs: Analog (V, mA)
Outputs: 2 Relay
Outputs: 4 Transistors
  • SIL3 and PLe certification
  • Safety functions equivalent to EN 61800-5-2
    (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
  • 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
  • 2 pulse inputs with format A, /A, B, /B [RS422]
  • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP]
    (for rotary encoder, proximity switches or commands)
  • Input frequency up to 500 kHz
  • Forced-guided redundant output relay (NO)
  • 4 control outputs with push-pull characteristic, short-circuit-proof,
    [HTL], each inverse and redundant
  • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
  • With signal splitter
  • Power supply 18 ... 30 V
  • Compact housing for 35 mm mounting top hat rail
  • (according to EN 60715)
  • Setup via USB port by operator software or plug-in display and
    programming unit BG230 (accessories)
Certified Safety Monitor with Multifunctional Inputs for HTL-, RS422- and SinCos-Sensors, without Signal Splitter

DS236

Certified Safety Monitor with Multifunctional Inputs for HTL-, RS422- and SinCos-Sensors, without Signal Splitter

Input format: Frequency (HTL, TTL)
Input format: SinCos (1 Vss)
Outputs: Analog (V, mA)
Outputs: 2 Relay
Outputs: 4 Transistors
  • SIL3 and PLe certification
  • Safety functions equivalent to EN 61800-5-2
    (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
  • 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
  • 2 pulse inputs with format A, /A, B, /B [RS422]
  • 2 pulse- or control inputs with format A, B, 90° [HTL / PNP]
    (for rotary encoder, proximity switches or commands)
  • Input frequency up to 500 kHz
  • Forced-guided redundant output relay (NO)
  • 4 control outputs with push-pull characteristic, short-circuit-proof,
    [HTL], each inverse and redundant
  • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
  • Power supply 18 ... 30 V
  • Compact housing for 35 mm mounting top hat rail
    (according to EN 60715)
  • Setup via USB port by operator software or plug-in display and
    programming unit BG230 (accessories)
Safety Speed Monitor for Incremental Encoders / Sensors

DS260

Safety Speed Monitor for Incremental Encoders / Sensors

Input format: Frequency (HTL, TTL)
Outputs: Analog (V, mA)
Outputs: 2 Relay
Outputs: 4 Transistors
  • SIL3 and PLe certification (depends ofn the used encoder / sensor arrangement)
  • Safety functions equivalent to EN 61800-5-2
    (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
  • 1 incremental encoder input with format A, /A, B, /B, Z, /Z
    [HTL differencial, RS422]
  • 8 control inputs [HTL / PNP]
  • Input frequency up to 500 kHz
  • 2 relay outputs 5... 250 VAC / VDC (NO)
  • 4 x 2 control outputs with push-pull characteristic, short-circuit-proof,
    [HTL], antivalent or equivalent redundant or simply used
  • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
  • Signal splitter
  • Power supply 18 ... 30 V
  • Wire monitoring of the sensor signals
  • Compact housing for 35 mm mounting top hat rail
    (according to EN 60715)
  • USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
  • BG200 operator panel for easy parameterization and display (optional)
Safety Speed Monitor for Incremental Encoders / Sensors

DS250

Safety Speed Monitor for Incremental Encoders / Sensors

Input format: Frequency (HTL, TTL)
Outputs: Analog (V, mA)
Outputs: 2 Relay
Outputs: 4 Transistors
  • SIL3 and PLe certification
  • Safety functions equivalent to EN 61800-5-2
    (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
  • 2 incremental encoder inputs with format A, /A, B, /B, Z, /Z
    [HTL differencial, HTL single ended, RS422]
  • 8 control inputs [HTL / PNP]
  • Input frequency up to 500 kHz
  • 2 relay outputs 5... 250 VAC / VDC (NO)
  • 4 x 2 control outputs with push-pull characteristic, short-circuit-proof,
    [HTL], antivalent or equivalent redundant or simply used
  • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
  • Signal splitter
  • Power supply 18 ... 30 V
  • Wire monitoring of the sensor signals
  • Compact housing for 35 mm mounting top hat rail
    (according to EN 60715)
  • USB interface in combination with the user interface OS6.0 for the parameterization of the safety speed monitor
  • BG200 operator panel for easy parameterization and display (optional)
Plug-in Display Unit

BG200

Plug-in Display Unit

  • Individual scalable process or speed indicator
  • Dual channel frequency indicator for visualization of the encoder frequency
  • Display of alarm and error codes
  • Touch screen with intuitive menu guidance
  • 1.54" OLED Display (128 x 64 Pixel)
  • Dimension: 50 x 80 x 15 mm (1,97 x 3,15 x  0,59")
Certified Safety Monitors with SinCos Encoder and Signal Splitter

DS240

Certified Safety Monitors with SinCos Encoder and Signal Splitter

Input format: SinCos (1 Vss)
Outputs: Analog (V, mA)
Outputs: 2 Relay
Outputs: 4 Transistors
  • SIL3 and PLe certification
  • Safety functions equivalent to EN 61800-5-2
    (SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS)
  • 1 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
  • 2 pulse- or control inputs with format A, B, 90°
    [HTL / PNP] (for rotary encoder, proximity switches or commands)
  • Input frequency up to 500 kHz
  • Forced-guided redundant output relay (NO)
  • 4 control outputs with push-pull characteristic, short-circuit-proof,
    [HTL], each inverse and redundant
  • Safety related 14 bit analog output for 4 ... 20 mA (scalable)
  • With signal splitter
  • Power supply 18 ... 30 V
  • Compact housing for 35 mm mounting top hat rail
    (according to EN 60715)
  • Setup via USB port by operator software or plug-in display and
    programming unit BG230 (accessories)