Product filter

  • Function
    • IO-Link Indicator
    Analog Value Indicator
    Incremental Indicator
    Position Indicator
    Process Value Indicator
  • Input format
    Input format
    Number of inputs
  • Outputs
    Outputs
  • Preselection
    Preselection
  • Display
    Display
  • Interface
    Interface
  • Supply voltage
    Supply voltage
  • Housing
    Housing

IO-Link Indicator

Products found: 1

Displays from the touchMATRIX® series can be equipped with different options. The new IO option offers touchMATRIX® displays the connection to the IO-Link world.

With regard to Industry 4.0, the process indicator with IO-Link device enables e.g. the digitization of conventional analog sensors. This results in a variety of innovative features for standard sensors such as the transmission of status information, the configuration of the devices during operation or the digital evaluation and scaling of analog sensors. This saves retooling and commissioning costs. Thanks to extensive monitoring, weak points can be detected and repaired even before a machine downtime occurs.

touchMATRIX® IO-Link Indicator

AX350/IO

touchMATRIX® IO-Link Indicator

Input format: Analog (V, mA)
Interface: IO-Link
  • 2 universal 16 bit analog inputs for ±10 V or 0/4 … 20 mA
  • 3 control inputs for HTL / PNP signals
  • Power supply 18 ... 30 VDC
  • 24 V auxiliary output for encoder supply
  • High accuracy reference output 10 V for 
    potentiometers > 1 kOhm
  • 3.78 x 1.89 inch norm panel housing and IP65 protection
  • Bright and high-contrast display with event-dependent color variations
  • Emulation of a 7-segment display inclusively icons and units
  • Intuitive and easy parameterization by plain text and touchscreen
  • Operating modes for visualization of INPUT 1, INPUT 2 or
    combinations of IN1 + IN2, IN1 - IN2, IN1 x IN2, IN1: IN2
  • Numerous features, e. g. Ttara, filters, averaging
  • Linearization with 24 control points

Option IO (= IO-Link Device)

  • Data transfer via COM3 (230,4 kBaud)
  • Cycle times < 3 msec
  • Process data IN 32 Byte (6 x process values from AX350):
    - Analog value 1 (scaled / linearized) and unit
    - Analog value 2 (scaled / linearized) and unit
    - Analog value 1 (scaled / linearized) with totalisation and unit
    - Analog value 2 (scaled / linearized) with totalisation and unit
    - Shortcut analog value 1 (scaled / linearized) with analog value 2  (scaled / linearized) and unit
    - Shortcut totalisator analog value 1 (scaled / linearized) with totalisator analog value 2 (scaled / linearized) and unit
  • Process data Out 8 Byte (2 x IO-Link process values to AX350):
    - IOL process value Out 1 with scaling, adjustable decimal point and programmable units
    - IOL process values Out 2 with scaling, adjustable decimal point and programmable units

Combinable with further options:

  • Option AC: Power supply 115 ... 230 VAC
  • Option AO: 16 bit analog output, 4 control outputs,
    serial RS232 interface
  • Option AR: 16 bit analog output, 4 control outputs,
    serial RS485 interface
  • Option CO: 4 control outputs, serial RS232 interface
  • Option CR: 4 control outputs, serial RS485 interface
  • Option RL: 2 relay outputs