Suitable for converting sinusoidal encoder signals into incremental output pulses. Further features e. g. adjustable multiplier, interpolation factor, divider and glitch filter are available.
- Encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
- Control input „Error Release“ for PNP signals [10 ... 30 VDC]
- Input frequency up to 400 kHz
- Pulse output with format A, /A, B, /B, Z, /Z [RS422]
- Pulse output with format A, B, 90° [HTL]
On-site indicator with EtherCAT interface. With resistive touchscreen and multicolor graphic display (red, green, yellow). Representation of plain text, symbols and units possible - recently also bargraph.
- EtherCAT interface
- 3 control inputs for remote release
IO-Link coupler with an SSI input and IO-Link interface.
- 1 SSI input (10 … 32 bit)
- for singleturn and multiturn encoders
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
IO-Link coupler with an incremental input and IO-Link interface.
- 1 incremental input (A, /A, B, /B)
- for HTL/TTL/RS422 and NPN/PNP/NAMUR encoders and sensors
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
IO-Link coupler with a strain gauge input and IO-Link interface.
- IO-Link coupler with a strain gauge input and IO-Link interface.
- 1 strain gauge input, 6-wire connection
- 3 VDC and 10 VDC bridge voltage per sensor connection
- 1 … 10 mV sensitivity
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
IO-Link coupler with four analog inputs (two voltage inputs and two current inputs) and IO-Link interface.
- 4 analog inputs for ±10 V or 0/4 ... 20 mA (2x current / 2x voltage)
- optionally 3 control inputs for PNP signals [10 ... 30 VDC]
- IO link interface
On-site indicator with PROFINET interface. With resistive touchscreen and multicolor graphic display (red, green, yellow). Representation of plain text, symbols and units possible.
- PROFINET interface
- 3 control inputs for remote release
Strain gauge measuring amplifier DM222 for connecting two strain gauge sensors and converting them into analog output signals.
- 2 strain gauge inputs, 6-wire connection
- 2 analog outputs ±10 V or 0/4 ... 20 mA, 16 Bit
- 3 VDC and 10 VDC bridge voltage per sensor connection
- 1… 10 mV sensitivity
Strain gauge indicator with a 6-wire connection for strain gauge full bridge sensors. With the help of all types of tension, pressure and force sensors, a precise and fast measurement is guaranteed for a large number of applications. These include hydraulic presses, rolling machines, bending machines and strength testing machines.
- Strain gauge input, 6-wire connection
- Input for pt100 and thermocouples (J and K)
- 3 control inputs for HTL / PNP signals
- Adjustable bridge voltage from 3 VDC to 10 VDC
The DM221 strain gauge measuring amplifier is used to connect one strain gauge sensor and convert it into analog output signals.
- 1 strain gauge input, 6-wire connection
- 1 analog output ±10 V or 0/4 ... 20 mA, 16 Bit
- 3 VDC and 10 VDC bridge voltage per sensor connection
- 1… 10 mV sensitivity
Impulse distributor for incremental encoders without potential separation between input and output.
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422 / HTL differential]
- Input frequency up to 500 kHz [HTL] or 1 MHz [RS422 / TTL]
- 4 push-pull outputs, formats corresponds to the input signals, but with individual assignment for each output
Impulse distributor for incremental encoders without potential separation between input and output.
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 500 kHz [HTL] or 1 MHz [RS422 / TTL]
- 8 push-pull outputs, formats corresponds to the input signals, but with individual assignment for each output
Impulse distributor for incremental encoders without potential separation between input and output. Outputs can be expanded with the EV224 and EV228 expansion modules.
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 500 kHz [HTL] or 1 MHz [RS422 / TTL]
- 8 push-pull outputs, formats corresponds to the input signals, but with individual assignment for each output
Expansion module for the impulse distributors GV228/EV without potential separation. For expanding by four more outputs
- 4 push-pull outputs, formats corresponds to the input signals, but with individual assignment for each output
- BUS interface for quick and easy connection of the modules
- Input frequency up to 500 kHz [HTL] or 1 MHz [RS422 / TTL]
Expansion module for the impulse distributor GV228/EV without potential separation. For expanding by eight more outputs
- 8 push-pull outputs, formats corresponds to the input signals, but with individual assignment for each output
- BUS interface for quick and easy connection of the modules
- Input frequency up to 500 kHz [HTL] or 1 MHz [RS422 / TTL]
Impulse distributor for incremental encoders with potential separation between input and output.
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 500 kHz [HTL] or 1 MHz [RS422 / TTL]
- 2 push-pull outputs, formats corresponds to the input signals, but with individual assignment for each output
Impulse distributor for incremental encoders with potential separation between input and output.
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422 / HTL differential]
- Input frequency up to 500 kHz [HTL] or 1 MHz [RS422 / TTL]
- 4 push-pull outputs, formats corresponds to the input signals, but with individual assignment for each output
Impulse distributor for incremental encoders with potential separation between input and output.
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 500 kHz [HTL] or 1 MHz [RS422 / TTL]
- 8 push-pull outputs, formats corresponds to the input signals, but with individual assignment for each output
Impulse distributor for incremental encoders with potential separation between input and output. Outputs can be expanded with the ET224 and ET228 expansion modules.
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 500 kHz [HTL] or 1 MHz [RS422 / TTL]
- 8 push-pull outputs, formats corresponds to the input signals, but with individual assignment for each output
Expansion module for the impulse distributors of the GT series with potential separation. For expanding by four more outputs
- 4 push-pull outputs, formats corresponds to the input signals, but with individual assignment for each output
- BUS interface for quick and easy connection of the modules
- Input frequency up to 500 kHz [HTL] or 1 MHz [RS422 / TTL]
Expansion module for the impulse distributors of the GT series with potential separation. For expanding by eight more outputs
- 8 push-pull outputs, formats corresponds to the input signals, but with individual assignment for each output
- BUS interface for quick and easy connection of the modules
- Input frequency up to 500 kHz [HTL] or 1 MHz [RS422 / TTL]
The Safety Motion Monitors for SinCos sensors are suitable for safety-related monitor tasks, e.g. direction of rotation, standstill, overspeed and underspeed.
- Safety functions equivalent to EN 61800-5-2
(SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS) - 1 encoder input with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 control inputs [HTL / PNP]
- Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof, [HTL],
each inverse and redundant - Safety related 14 bit analog output for 4 ... 20 mA (scalable)
The FP210 signal converter detects frequencies via its input and converts them into a parallel binary, gray code or BCD format.
- Frequency inputs A, B [HTL], A, / A, B, / B [RS422, HTL]
- 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
- Input frequency up to 1 MHz
- 25-bit parallel output push-pull in BCD, binary or gray code
The IP210 signal converter receives signals via its SSI input and converts them into a parallel binary, Graycode or BCD format.
- SSI input with format DATA+, DATA-, CLOCK+, CLOCK- up to 32 Bit
- 3 control inputs (Hold) for PNP signals [10 ... 30 VDC]
- Input frequency up to 1 MHz
- 25 Bit parallel output with push-pull characteristic with format BCD, binary or Gray-Code
The ZP210 signal converter is used to convert pulses into a parallel signal (binary, gray code or BCD format).
- Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
- Input frequency up to 1 MHz
- 25-bit parallel output push-pull in BCD, binary or Gray code
Signal converter with start-stop input for absolute transducers and magnetostrictive sensors and parallel output (binary, gray code or BCD format).
- Start-stop interface (Start_Stop, / Start_Stop); (Init_In, / Init_In); (Init_Out, / Init_Out)
- 3 control inputs (hold) for PNP signals [10 ... 30 VDC]
- 25-bit parallel output push-pull in BCD, binary or Gray code
Extremely fast universal converter that converts analog input signals into a frequency or position. The output is as an incremental signal, an SSI absolute value as well as in a serial RS232 / RS485 format
- Scalable 14 bit analog input for ±10 V or 0/4 ... 20 mA
- 4 control inputs for PNP signals [10 ... 30 VDC]
- Pulse output with format A, B, 90° [HTL] or A, /A, B, /B, Z, /Z [RS422]
- SSI output with format DATA+, DATA-, CLOCK+, CLOCK- up to 25 bit
Process indicator with resistive touch panel and multi-colour graphic display (red, green, yellow). Visualization of plain text, symbols and units. Arbitrarily combinable, modular configuration with analog output, switching outputs, relay, serial interface (Modbus) and 115 ... 230 VAC.
- 2 universal 16 bit analog inputs for ±10 V or 0/4 … 20 mA
- 3 control inputs for HTL / PNP signals
- High accuracy reference output 10 V for potentiometers > 1 kOhm
Decentralized indicator with IO-Link device for displaying two process data. With resistive touch panel and multi-colour graphic display (red, green, yellow). Visualization of plain text, symbols and units. Arbitrarily combinable, modular configuration with analog output, switching outputs, relay, serial interface (Modbus) and 115 ... 230 VAC.
- IO-Link-Device V1.1
- 2 universal 16 bit analog inputs for ±10 V or 0/4 … 20 mA
- 3 control inputs for HTL / PNP signals
- High accuracy reference output 10 V for potentiometers > 1 kOhm
IO-Link-Device V1.1 configuration of the individual configuration of the touchMATRIX® process displays. Combinable with various options.
» More Information» Add to cartPerformance as AX345, with serial RS232 / RS485 interface.
Safety Speed Monitor for incremental encoders / sensors for monitoring of ramp, underspeed, overspeed, standstill an direction of rotation, with cable break monitoring of the sensor signals. Up to SIL3/PLe with one equally certified sensor.
- Safety functions equivalent to EN 61800-5-2
(SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS) - 1 incremental encoder input with format A, /A, B, /B, Z, /Z
[HTL differencial, RS422] - 8 control inputs [HTL / PNP]
- Input frequency up to 500 kHz
- 2 relay outputs 5... 250 VAC / VDC (NO)
- 4 x 2 control outputs with push-pull characteristic, short-circuit-proof,
[HTL], antivalent or equivalent redundant or simply used - Safety related 14 bit analog output for 4 ... 20 mA (scalable)
Performance as DS260, but up to SIL3/PLe with two independent, non-certified sensors and two incremental encoder Inputs.
The plug-in display unit BG200 is used for the motrona safety devices of the DS series. This devices contains a huge variety of visualization applications. Thanks to its intuitive operation, it is fast, simple and flexible to use.
The BG200 offers the following features on the safety device:
- Dual channel frequency indicator
- Individual scalable for speed indicator, production rates, etc.
- Visualization of operating and error mode
Individual configuration of the touchMATRIX® process displays are possible with various options.
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16 bit analog output, 4 control outputs,
serial RS232 interface - Option AR: 16 bit analog output, 4 control outputs,
serial RS485 interface - Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
- Option IO: IO-Link Device V1.1
HTL frequency counter, tachometer, speed counter with resistive touchscreen and multi-color graphic display (red, green, yellow). Digital indicator for incremental encoders or sensor signals.
- Pulse input with format A, B, 90° [HTL], single channel as an option
- HTL inputs for encoder and sensors with NPN / PNP or NAMUR switching characteristics
- Input frequency up to 250 kHz
- 3 control inputs for HTL / PNP signals
Individual configuration of the touchMATRIX® process displays are possible with various options.
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16 bit analog output, 4 control outputs,
serial RS232 interface - Option AR: 16 bit analog output, 4 control outputs,
serial RS485 interface - Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
"High-End" device with 2 incremental HTL / RS422 control inputs. Input frequency up to 1 MHz and a switchable encoder supply of 5 / 24 VDC. All other functions equal to DX350.
Individual configuration of the touchMATRIX process displays are possible with various options.
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16 bit analog output, 4 control outputs,
serial RS232 interface - Option AR: 16 bit analog output, 4 control outputs,
serial RS485 interface - Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
The MX350 multifunction indicator uses HTL signals. It is capable of measure and display two sizes, such as speed and length (quantity) simultaneously.
- Pulse input with format A, B, 90° [HTL], single channel as an option
- HTL inputs for encoder and sensors with NPN / PNP or NAMUR switching characteristics
- Input frequency up to 250 kHz
- 3 control inputs for HTL / PNP signals
Version with incremental HTL / RS422 encoder input (inverted) and an input frequency up to 1 MHz and a switchable encoder supply of 5/24 VDC. All other functions equal to MX350.
Combi position indicator with simultaneous measurement process for absolute position and speed. Both values can be shown in parallel on the display. The parameters are freely selectable.
- SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
- SSI clock frequencies up to 1 MHz
- Master or Slave operation
- For single turn and multi turn encoders with 10 … 32 Bit
"High-end" version with wire break monitoring of the SSI data line (except SSI clock). Switchable encoder supply of 5 / 24 VDC. Can only be used as SSI master. All other features like IX350.
Precise up / down counter with extensive programmable operating modes and static input.
- Pulse input with format A, B, 90° [HTL], [TTL] as an option
- Static input for Set / Reset [HTL]
- Scalable 14 bit analog output ±10 V or 0/4 ... 20 mA
Precise up / down counter with extensive programmable operating modes and static input with 2 preset values and 2 transistor outputs.
- Pulse input with format A, B, 90° [HTL], [TTL] as an option
- Static input for Set / Reset [HTL]
- 2 preset values
- 2 transistor outputs
Pulse counter (HTL) with resistive touchscreen and multi-color graphic display (red, green, yellow). Digital display for incremental encoders or sensor signals.
- Pulse input with format A, B, 90° [HTL], single channel as an option
- HTL inputs for encoder and sensors with NPN / PNP or NAMUR switching characteristics
- Input frequency up to 250 kHz
- 3 control inputs for HTL / PNP signals
Individual configuration of the touchMATRIX pulse counters are possible with various options.
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16 bit analog output, 4 control outputs,
serial RS232 interface - Option AR: 16 bit analog output, 4 control outputs,
serial RS485 interface - Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
"High-End" device with 2 incremental HTL / RS422 control inputs. Input frequency up to 1 MHz and a switchable encoder supply of 5 / 24 VDC. All other functions equal to DX350.
Individual configuration of the touchMATRIX® pulse counters are possible with various options. All options can be combined.
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16 bit analog output, 4 control outputs,
serial RS232 interface - Option AR: 16 bit analog output, 4 control outputs,
serial RS485 interface - Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
Low-cost Controllers for Synchronizaiton. Speed ratio adjustable by keypad.
- 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 300 kHz
- 4 fast transistor outputs, with push-pull charackteristics, short-circuit-proof
[5 … 30 VDC] - Scalable 14 bit analog output (±10 V or 0/4 … 20 mA)
Performance as BY340, but with 4 relays and front-side thumbwheel switches for speed ratio adjustment.
Fieldbus indicator for PROFIBUS process values.
- Power supply 10 ... 30 VDC
- Compact norm panel housing
- 6 digits LED display with 15 mm height
Fieldbus display for CAN bus actual values and any parameters.
- Power supply 10 ... 30 VDC
- Compact norm panel housing
- 6 digits LED display with 15 mm height
Remote control for PROFIBUS networks for panel mounting.
- Power supply 10 ... 30 VDC
- Compact norm panel housing
- Preset range: 6 digits or 5 digits with sign
Combination of PROFIBUS display and remote control in one housing. Availability on request.
Combination of CAN-Bus display and remote control in one housing.
This simulator of incremental encoder signals also produces counted pulse sequences of any pulse number. Availability on request.
The analog to frequency converter is suitable for use as a frequency generator. The regulation of the input voltage can be done via a potentiometer or the operating software OS10.0.
- Scalable 14 bit analog input for ±10 V or 0/4 ... 20 mA
- 4 control inputs for PNP signals [10 ... 30 VDC]
- Pulse output with format A, B, 90° [HTL] or A, /A, B, /B, Z, /Z [RS422]
- SSI output with format DATA+, DATA-, CLOCK+, CLOCK- up to 25 bit
The signal converter can digitize analog measured quantities and transmit them via its serial interface. That is why it can be used as a data logger.
- Scalable 14 bit analog input for ±10 V or 0/4 ... 20 mA
- 4 control inputs for PNP signals [10 ... 30 VDC]
- Pulse output with format A, B, 90° [HTL] or A, /A, B, /B, Z, /Z [RS422]
- SSI output with format DATA+, DATA-, CLOCK+, CLOCK- up to 25 bit
Cost-effective, powerful gateway for connecting motrona devices to a PROFIBUS (DPV1).
Simple operating unit for entering and readout individual parameters via serial interface. Suitable as a remote display for all motrona devices with serial interface.
Affordable compact power supply unit for all motrona devices with 24 VDC input / 15 W output (Lambda).
suitable for display units with front dimension 96 x 48 mm.
suitable for display units with front dimension 96 x 48 mm (fits not to Profibus indicator PB340).
This set consists of an USB to RS232 converter compatible to all existing Windows versions, including a serial RS232 cable for connection between converter and motrona unit.
One connector Sub-D-9 (male) and one connector Sub-D-9 (female), cable length 3 meters (approx. 10 feet).
USB connector type A on type B. Length 1,8 m.
for connection between PC and the motrona unit UZ210. Both connectors are type A, cable length 2 m (approx. 6.5 feet).
1 connector Sub-D-9 (male) and 1 connector Sub-D-9 (female).
USB 2.0 cable, type A connector to Mini B, length 1,8 m, black.
To increase the protection class with dusty or wet environment, several types of protection caps are available for motrona units.
Scalable compact digital display for visualization of analog standard signals.
- Scalable 14 bit analog input for 0 ... 10 V or 0/4 ... 20 mA
- Power supply 24 VDC
Universally scalable process indicator with two 14 bit analog inputs and extensive programmable functions such as tara, programmable linearization, etc. Suitable for visualization of measurement values, sums, differences and ratio.
- 2 analog inputs
- 2 limit values / output relays
- Power supply 24 VDC
- Serial RS232 / RS485 interface (switchable)
Performance as AX345, with scalable analog output.
Performance as AX345, with 2 preset values for the control of 2 transistor switching outputs.
» More InformationThe DP350 touchMATRIX® series is suitable for absolute transducers and magnetostrictive sensors. Through its start-stop interface, the device serves the transonic distance measurement. Furthermore, the device has a resistive touchscreen with multi-colored graphic display (red, green, yellow).
- Start-stop interface for absolute transducers and magnetostrictive sensors
- Adjustable frequency of the init pulses from 62.5Hz to 5 kHz
- 3 control inputs for HTL / PNP signals
SSI indicator unit for evaluation of single- or multi-turn absolute encoders. Suitable for all SSI formats and codes up to 25 bits. Free scalability and zero definition. Programmable bit blanking, linearization, concentricity function and many other funtions. Operation in master and slave mode.
- SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
- 3 control inputs for PNP / NPN / signals [10 ... 30 VDC]
- SSI frequency range 100 Hz ... 1 MHz
- 2 preset values
- 2 transistor outputs
Position indicator for absolute encoders with resistive touchscreen and multi-color graphic display (red, green, yellow). Digital indicator for incremental encoders or sensor signals.
- SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
- SSI clock frequencies up to 1 MHz
- Master or Slave operation
- For single turn and multi turn encoders with 10 … 32 Bit
Individual configuration of the touchMATRIX® position displays are possible with various options.
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16 bit analog output, 4 control outputs,
serial RS232 interface - Option AR: 16 bit analog output, 4 control outputs,
serial RS485 interface - Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
"High-end" version with wire break monitoring of the SSI data line (except SSI clock). Switchable encoder supply of 5 / 24 VDC. Can only be used as SSI master. All other features like IX350.
Individual configuration of the touchMATRIX® position displays are possible with various options.
- Option AC: Power supply 115 ... 230 VAC
- Option AO: 16 bit analog output, 4 control outputs,
serial RS232 interface - Option AR: 16 bit analog output, 4 control outputs,
serial RS485 interface - Option CO: 4 control outputs, serial RS232 interface
- Option CR: 4 control outputs, serial RS485 interface
- Option RL: 2 relay outputs
Versatile indicator unit for SSI encoder, with 2 relay outputs and serial interface.
- SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
- 3 control inputs for PNP / NPN / signals [10 ... 30 VDC]
- 2 output relays with potential free change-over contact
- Power supply 24 VDC
- Serial RS232 / RS485 interface Schnittstelle (switchable)
SSI indicator unit for evaluation of single- or multi-turn absolute encoders. Suitable for all SSI formats and codes up to 25 bits. Free scalability and zero definition. Programmable bit blanking, linearization, concentricity function and many other funtions. Operation in master and slave mode.
- SSI input with format DATA+, DATA-, CLOCK+, CLOCK-
- 3 control inputs for PNP / NPN / signals [10 ... 30 VDC]
- SSI frequency range 100 Hz ... 1 MHz
- Power supply 115 / 230 VAC and 24 VDC
Performance as IX345, but additionally with scalable 14 bit analog output.
Performance as IX345, but additionally with serial RS232 / RS485 interface (switchable).
» More InformationThe position indicators with dual SSI encoder input have been designed to close a gap with multiple indicating and counting applications, which cannot be accomplished by the standard SSI indicators or incremental counters available on the market. Many applications require to evaluate the signals of two SSI measuring systems, and to compare the results with respect to the sum or the difference. In certain applications it is necessary to compare position signals from an SSI encoder with other information coming from an incremental encoder.
- 2 scalable inputs with format DATA+, DATA-, CLOCK+, CLOCK- [SSI, absolute]
or A, /A, B, /B [RS422, incremental] - 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1 MHz
- 4 fast transistor outputs with push-pull characteristic,
short-circuit-proof [5 ... 30 VDC] - Power supply 24 VAC and 17 ... 40 VDC
Performance as ID330, but with scalable 14 bit analog output.
Performance as IA330, but with 6 digit display.
Performance as ID330, but with 4 output relays and dimension 96 x 96 x 140 mm (3.78 x 3.78 x 5.51 ").
Performance as ID630, but additionally with 2 front-panel preselections for the switching function.
Performance as ID630, but additionally with 4 front-panel preselections for the switching function.
Performance as ID630, but with 6 digit display.
Performance as ID640, but additionally with 2 front-panel preselections for the switching function.
Performance as ID640, but additionally with 4 front-panel preselections for the switching function.
Performance as ID630, but additionally with scalable 14 bit analog output.
Performance as IA630, but additionally with 2 front-panel preselections for the switching function.
Performance as IA630, but additionally with 4 front-panel preselections for the switching function.
Performance as IA630, but with 6 digit display.
Performance as IA640, but additionally with 2 front-panel preselections for the switching function.
Performance as IA640, but additionally with 4 front-panel preselections for the switching function.
Universally programmable incremental display counter in miniature housing.
- Pulse input with format A, B, 90° [HTL]
- Static input for Set / Reset [HTL]
- Input frequency up to 20 kHz
Up / Down pulse counter with 2 relays and serial RS232 / RS485 interface.
- Pulse input with format A, B, 90° [HTL], [TTL] as an option
- Static input for Set / Reset [HTL]
- 2 relay outputs
- Input frequency up to 100 kHz
- Power supply 24 VDC
- Serial RS232 / RS485 interface (switchable)
Precise up / down counter with extensive programmable operating modes and static input. Basic version without outputs.
- Pulse input with format A, B, 90° [HTL], [TTL] as an option
- Static input for Set / Reset [HTL]
- Input frequency up to 100 kHz
- Power supply 115 / 230 VAC and 24 VDC
Performance as DX345, but with RS232- / RS485 interface.
» More InformationFast universal counter up to 1 MHz with analog output and 8 digit display.
- 2 scalable inputs with format A, /A, B, /B
[HTL / TTL / RS422, single channel, dual channel, symmetric or asymmetric] - 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1 MHz
- Scalable 14 bit analog output ±10 V or 0/4 … 20 mA
- 4 fast transistor outputs with push-pull characteristic, short-circuit-proof
[5 ... 30 VDC]
Performance as ZA330, but without analog output.
Performance as ZA330, but with 6 digit display.
Performance as ZD330, but with 6 digit display.
The universal counters of the ZD / ZA / ZR 630-640 series are equipped as standard with output relay, dimensions 96 x 96 x 140 mm (3.78 x 3.78 x 5.51 ").
The range of functions corresponds otherwise to that of the ZD / ZA / ZR 330-340 series.
- 2 scalable inputs with format A, /A, B, /B
[HTL / TTL / RS422, single channel, dual channel, symmetric or asymmetric] - 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1 MHz
- 4 fast transistor outputs with push-pull characteristic,
short-circuit-proof [5 ... 30 VDC] - 4 outputs relays
Performance as ZD630, with 2 front-panel preselections for the switching function.
» More InformationPerformance as ZD630, but with 4 front-panel preselections for the switching function.
» More InformationPerformance as ZD630, but with 6 digit Display with 15 mm height
» More InformationPerformance as ZD640, with 2 front-mounted thumbwheel switches.
» More InformationPerformance as ZD640, with 4 front-mounted thumbwheel switches.
Performance as ZD630 with scalable analog output.
Performance as ZD632, with analog output.
» More InformationPerformance as ZD634 with scalable analog output.
» More InformationPerformance as ZA630, but with 6 digit display with 15 mm height.
» More InformationPerformance as ZA632, but with 6 digit Display with 15 mm height.
» More InformationPerformance as ZA634,but with 6 digit Display with 15 mm height.
Programmable indicator for reliable measurement of RPM, speed and frequency.
- Single channel pulse input [HTL]
- Input frequency up to 20 kHz
- Power supply 24 VDC
Tachometer / frequency meters with 6 digit LED display, two independent pulse inputs and analog output.
- 2 scalable inputs with format A, /A, B, /B
[HTL / TTL / RS422, single channel, dual channel, symmetric or asymmetric] - 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1 MHz
- 4 fast transistor outputs with push-pull characteristic, short-circuit-proof
[5 ... 30 VDC] - Scalable 14 bit analog output ±10 V or 0/4 ... 20 mA
Performance as SA340, but without analog output.
Performance as SA340, but with 4 relays and dimension of 96 x 96 x 140 mm (3.78 x 3.78 x 5.51 ").
Performance as SA640, but additionally with 2 front-panel preselections for the switching function.
» More InformationPerformance as SA640, but additionally with 4 front-panel preselections for the switching function.
Performance as SD340, but with 4 relays and dimension of 96 x 96 x 140 mm (3.78 x 3.78 x 5.51 ").
Performance as SD640,but additionally with 2 front-panel preselections for the switching function.
» More InformationPerformance as SD640, but additionally with 4 front-panel preselections for the switching function.
The SRC30/EL universal safety switching device offers comprehensive protection with three safe relays and can be operated with one or two channels. It supports a wide range of encoders, such as emergency stop buttons, mechanical and non-contact safety switches as well as safety components with OSSD outputs. With EN 81-20 and EN 81-50 certifications, the SRC30/EL is particularly suitable for elevator monitoring and also offers an ideal solution for safety gate monitoring of machines and systems. A versatile safety system at the highest level.
- 2-channel pulse input
- 3 safe relay contacts
- Use up to SIL3/PLe, category 4 (EN ISO 13849-1 / EN IEC 62061 / EN 61508)
- Compact housing for mounting on 35 mm top-hat rail (in accordance with EN 60715)
Performance as DS240, without signal splitter.
Performance as DS240, but different input configuration.
- Safety functions equivalent to EN 61800-5-2
(SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS) - 2 encoder inputs with format SIN+, SIN-, COS+, COS- [1 Vss]
- 2 pulse inputs with format A, /A, B, /B [RS422]
- 2 pulse- or control inputs with format A, B, 90° [HTL / PNP]
(for rotary encoder, proximity switches or commands) - Input frequency up to 500 kHz
- Forced-guided redundant output relay (NO)
- 4 control outputs with push-pull characteristic, short-circuit-proof,
[HTL], each inverse and redundant - Safety related 14 bit analog output for 4 ... 20 mA (scalable)
Performance as DS230, without signal splitter.
Compact monitor for monitoring speed, direction of rotation and standstill.
- Power supply 115 / 230 VAC and 18 ... 30 VDC
- Input frequency up to 200 kHz
- 4 opto-isolated transistor outputs for speed control, left motion, right motion and standstill
As part of our STOCK SALE, we offer this reliable and proven speed monitor at a special price of € 99.00 net ex works (retail price € 224.00). Subject to availability.
Electronic monitor for monitoring left / right rotation and standstill. With universal pulse inputs for all common incremental encoders and sensors.
- Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422],
also possible for single channel - Input frequency up to 500 kHz
- 2 output relays with potential-free change-over contact and
2 transistor outputs with High-Side-Driver, short-circuit-proof, [7 ... 30 VDC]
Compact device for monitoring overspeed, underspeed, standstill and direction of rotation with universal inputs for incremental encoders, proximity switches, light barriers or sensors.
- Pulse input with format A, B, 90° [HTL] or A, /A, B, /B [RS422],
also possible for single channel - Input frequency up to 1 MHz
- 3 output relays
- 14 Bit analog output for ±10 V or 0/4 ... 20 mA
Performance as DZ260, but with 3 fast transistor switching outputs instead of relays.
Performance as DZ260, without relay.
Performance as DZ260, without analog output.
The plug-in display and programming unit BG230 is used for the motrona safety devices of the DS230 - DS246 series. This devices contains a huge variety of functions and options of applications. Thanks to its intuitive operation, it is fast, simple and flexible to use. Easy "copy & paste" of system parameters allows the quick transfer to other devices with the same or similar configuration.
The BG230 offers the following features on the safety device:
- Dual channel frequency indicator
- Individual scalable for speed indicator, production rates, etc.
- Editing and saving of the BG230 scaling and safety devices parameters
- Editing and copying of the safety devices parameters
- Visual error messaging
Multi-function device with operating modes for incremental encoders, SSI absolute encoders or encoders with start-stop interface..
- Pulse input in format A, B, 90° [HTL] or A, /A, B, /B [RS422],
single-ended also possible - Input frequency up to 1 MHz
- 4 control outputs
- 14 Bit analog output for ±10 V or 0/4 ... 20 mA
Perfomances as DZ260, without analog output but with 3 transistor outputs.
Motion monitor with position display. Suitable for monitoring for drift, shaft fracture, torsion and slip.
- 2 scalable inputs with format A, /A, B, /B [HTL / TTL / RS422,
single channel, dual channel, symmetric or asymmetric] - 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 1 MHz
- 4 fast transistor outputs with push-pull characteristic,
short-circuit-proof [5 ... 30 VDC] - 4 potential-free output relays
Motion monitor for control and monitoring of admissible and impermissble operating conditions on machinery systems, e. g. speed, standstill, direction of rotation, position, drift, torsion, shaft fracture, slip, illegitimate motion sequences, etc.
- 2 Pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for PNP / NPN / Namur signals [10 ... 30 VDC]
- 6 logical inputs for PNP signals [10 ... 30 VDC]
- Input frequency up to 500 kHz
- 4 fast transistor outputs with push-pull characteristic,
short-circuit-proof [5 ... 30 VDC] - 4 forced-guided redundant output relays with potential free change-over contact
Incremental encoder with emphasis on frequency or velocity tasks.
Functions such as links (eg A + B), scaling, filters, start-up bridging ... etc.
- Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
- Input frequency up to 1 MHz [RS422], 200 kHz [HTL]
- Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
- USB interface and RS232/RS485-interface for configuration and serial readout
Versatile f / U or f / I converter with 2 frequency inputs and RS232 interface.
- Pulse inputs with format A, B, 2 x 90° [HTL] or A, /A, B, /B [TTL / RS422]
- Input frequency up to 1 MHz [RS422] or 200 kHz [HTL]
- Scalable 14 bit analog output for ±10 V or 0/4 ... 20 mA
Multifunctional unit with operating modes for incremental or SSI absolute encoder.
For SSI absolut encoder: Functions as wire breakage monitoring, bit blanking, concentricity functions, scaling, etc.
- SSI input DATA+, DATA-, CLOCK+, CLOCK- [RS422], 32 Bit
- SSI clock frequency up to 1 MHz
- Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
- USB interface and RS232/RS485-interface for configuration and serial readout
Signal converter with SSI interface for processing absolute position values into current and voltage values.
Selectable SSI master or slave mode and programmable concentricity functions, bit blanking and many more.
- SSI input with format DATA+, DATA-, CLOCK+, CLOCK- up to 25 bit
- Clock frequency 100 Hz ... 1 MHz
- Scalable 14 bit analog output for ±10 V or 0/4 ... 20 mA
Extremely powerful signal converter for converting SSI absolute values ??and serial data into a parallel binary, gracode or BCD format.
- SSI input with format DATA+, DATA-, CLOCK+, CLOCK- up to 25 Bit
- Clock frequency up to 1 MHz
- Control input (hold) for PNP signals [10 ... 30 VDC]
- 25 bit parallel output with push-pull characteristic with format BCD, binary or Gray-Code
The signal converter PR210 converts the data of a parallel interface (BCD, binary or graycode) into a serial RS232 or RS485 format.
- 20 bit parallel input with format BCD, binary or Gray-Code
- Input frequency: fast encoder 5 kHz, auto-transmit / data logging 0.5 kHz
- 4 status outputs, with push-pull characteristic, short-circuit-proof [5 ... 30 VDC]
Signal converter for the operating modes as pulse counter and position converter.
Functions as linking (e.g. A+B), scaling, filtering, start-up supression ... etc.
- Pulse inputs A, B [HTL], A, /A, B, /B [RS422, HTL]
- Input frequency up to 1 MHz [RS422], 200 kHz [HTL]
- Analog output ±10 V or 0/4 ... 20 mA, 16 Bit
- USB interface and RS232/RS485-interface for configuration and serial readout
Suitable to convert counting process of an incremental counter to an analog output and also converts sum A + B and difference A - B.
- Pulse inputs with format A, B, 2 x 90° [HTL] or A, /A, B, /B [RS422]
- Input frequency up to 1 MHz [RS422] or 200 kHz [HTL]
- Scalable 14 bit analog output for ±10 V or 0/4 ... 20 mA
Fiber optic transmitter module for transmitting incremental encoder and sensor signals with a transmission distance of up to 3000 m at an optical wavelength of 1300 nm. Converts the encoder signal into an optical signal.
- 4 independent input channels with format A, B, C, D [HTL] or
A, /A, B, /B, C, /C, D, /D [RS422],
also possible for single channel - 4 output channels with format A, B, C, D [HTL] or
A, /A, B, /B, C, /C, D, /D [RS422] - Maximum input frequency 1 MHz
Receiver module for the signal data transmitted by the transmitter module LW213. Converts the optical signals back to the incremental format. Performance as LW213.
Fiber optic transmitter module for the transmission of incremental encoder and sensor signals with a transmission distance of up to 2000 m with an optical wavelength of 850 nm. Otherwise, version as LW213.
Receiver module for the signal data transmitted by the transmitter module LW215. Converts the optical signals back to the incremental format. Performance as LW215.
Fiber optic (send-) module for SSI rotary pulse encoders and absolute measuring systems. Used to convert to optical signals and reliable transmission up to 2000 meters, also by explosive areas. Resistant to extremely strong electromagnetic fields.
- 1 SSI input / output channel [RS422] with format DATA+, DATA-, CLOCK+, CLOCK-
- 1 Error input (LW217) resp. 1 open-drain-output (LW218)
- Maximum input frequency 1 MHz
Optical fiber receiving module for the signal data transmitted by the transmitting module LW217. Converts the optical signals back to the SSI format. Performance as LW217.
Universal interface using with incremental measuring systems.
- Pulse input in format A, /A, B, /B, Z, /Z [RS422, HTL] or A, B, Z [HTL]
- Input frequency up to 1 MHz
- Pulse output in format A, /A, B, /B, Z, /Z [RS422, HTL] or A, B, Z [HTL]
This universal converter allows the conversion of incremental signals into pulse signals with a static direction output and vice versa, as well as a potential separation of input and output.
- 1 pulse input with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 500 kHz
- 1 pulse output with format A, /A, B, /B, Z, /Z [RS422, HTL]
- Power supply 5 ... 30 VDC
Level converter for incremental 10 ... 30 V encoders from HTL (A, B, Z) to TTL / RS422 format incl. the inverted signals (/A, /B, /Z). No potential separation.
- Pulse input with format A, B, Z [HTL] (10 ... 30 V)
- Input frequency max. 200 kHz
- Pulse output with format A, /A, B, /B, Z, /Z [RS422 / TTL]
- Power supply 5 VDC
Performance as PU202, but converts TTL / RS422 signals (A, / A, B, / B, Z, / Z) to an HTL format with an output level of 10 ... 30 V.
Universal encoder interface for level conversion, distribution and electronic switching of incremental encoder signals.
- 2 pulse inputs with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 250 kHz for asymmetrical and up to 1 MHz for symmetric signals
- 2 pulse outputs with format A, B, Z [HTL] or A, /A, B, /B, Z, /Z [TTL / RS422],
each output adjustable separately
Level converter and direction decoder for incremental signals A, B, Z in both directions. Includes programmable pulse splitter. Input / output without potential separation.
- Pulse input with format A, /A, B, /B, Z, /Z [RS422] or A, B, Z [HTL]
- Input frequency up to 300 kHz
- Pulse output with format A, /A, B, /B, Z, /Z [RS422] or A, B, 90° [HTL]
Signal converters and signal distributors for encoders or measuring systems with sine-cosine signals. The SV210 has 2 SinCos outputs and 2 incremental outputs (HTL, TTL / RS422).
- 1 encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
- Maximum sinus input frequency 500 kHz with max. 200 ns conversion time
- 2 signal outputs with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
- 2 pulse outputs with format A, /A, B, /B, Z, /Z [RS422, TTL, HTL]
The PV210 extends our product segment of transonic signals by a converter that transforms start-stop signals into analog or serial signals.
- Start-stop interface for absolute transducers and magnetostrictive sensors
- Adjustable frequency of the init pulses from 62.5 Hz to 5 kHz
- Analog output ± 10 V, 0/4 ... 20 mA, 16 bit
- USB interface and RS232/RS485-interface for configuration and serial readout
Puls distributor with level converter and switching.
- 2 pulse inputs with format A, B, Z [HTL] or
A, /A, B, /B, Z, /Z [TTL / RS422] - Input frequency up to 250 kHz for asymmetrical and up to 1 MHz for symmetric signals
- 2 output channels with format A, B, Z [HTL] oder
A, /A, B, /B, Z, /Z [TTL / RS422], each output adjustable separately
Single pulse distributor for incremental encoder signals.
- 1 pulse input with format A, /A, B, /B, Z, /Z
- Input frequency 750 kHz [TTL / RS422] or 300 kHz [HTL]
- 2 pulse outputs with format A, /A, B, /B, Z, /Z
with individual adjustable output levels [HTL, RS422]
Impulse distributor for incremental encoder with potential separation between input and output. Short-circuit-proof supply voltage for the encoder and extended temperature range -20°C ... +60°C.
- 1 pulse input with format A, B, Z [HTL] or
A, /A, B, /B, Z, /Z [RS422] - Input frequency up to 200 kHz [HTL] or 500 kHz [RS422 / TTL]
- 8 push-pull outputs, formats corresponds to the input signals, but with individual assignement for each output
Performance as GV460, but with 4 outputs.
Low-cost distributor for incremental signals with electrical isolation between input and output.
- 1 Pulse input with format A, B, Z [HTL] or
A, /A, B, /B, Z, /Z [RS422] - Input frequency up to 200 kHz [HTL] or 500 kHz [RS422 / TTL]
- 8 push-pull outputs, formats corresponds to the input signals,
but with individual assignement for each output
Performance as GV470, but with 4 outputs.
» More InformationSignal distributor of the upper class with full electrical isolation of all channels and the power supply. Short-circuit-proof auxiliary voltage for the encoder supply and an extended temperature range from -20 ° C ... 60 ° C.
- 1 pulse input with format A, B, Z [HTL] or
A, /A, B, /B, Z, /Z [RS422] - Input frequency from 200 kHz [HTL] to 500 kHz [RS422 / TTL]
- 8 push-pull outputs, formats corresponds to the input signals, but with individual assignment for each input
Performance as GV480, but with 4 outputs.
Encoder switch for contactless and bounce-free switching of two
SSI sensors on an SSI master. Cascadable with other devices.
- 2 SSI inputs with format DATA+, DATA-, CLOCK+, CLOCK- [RS422]
- Cut-off frequency 100 kHz ... 1 MHz
- 1 SSI output with format DATA+, DATA-, CLOCK+, CLOCK- [RS422]
Encoder switch with 20 encoder inputs, 2 encoder outputs and 2 x 6 control inputs. Depending on the configuration of the control inputs, the device switches the signal at the input (1 - 20) to the respective output (OUT1 - 2).
- Pulse input with format A, /A, B, /B, Z, /Z [RS422]
- Input frequency up to 1 MHz
- 2 encoder outputs for TTL / RS422
Universal interface using with incremental measuring systems.
- Pulse input in format A, /A, B, /B, Z, /Z [RS422, HTL] or A, B, Z [HTL]
- Input frequency up to 1 MHz
- Pulse output in format A, /A, B, /B, Z, /Z [RS422, HTL] or A, B, Z [HTL]
Universal pulse and frequency multiplier for incremental signals of rotary pulse encoders and other measuring systems. Impulse scatter multiplication over proportional or reciprocal factor.
- Pulse input with format A, B, 90° [HTL] or A, /A, B, /B, Z, /Z [RS422]
- 4 control inputs for PNP signals [10 ... 30 VDC]
- Input and output frequency up to 1 MHz
- Pulse output with format A, /A, B, /B, Z, /Z and push-pull characteristic,
[5 ... 30 VDC]
Signal distributors and pulse splitters for sine-cosine encoders or measuring systems. With 2 SinCos outputs and 2 incremental outputs (HTL, TTL / RS422).
- 1 encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
- Maximum sinus input frequency 500 kHz with max. 200 ns conversion time
- 2 signal outputs with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
- 2 pulse outputs with format A, /A, B, /B, Z, /Z [RS422, TTL, HTL]
Signal distributor for SinCos encoders. Distributes the input signals of a sine-cosine encoder or measuring system to four homogeneous output channels. Performance as SV210.
Suitable for converting sinusoidal encoder signals into incremental output pulses. Further features e. g. adjustable multiplier, interpolation factor, divider and glitch filter are available.
- Encoder input with format SIN+, SIN-, COS+, COS-, REF+, REF- [1 Vss]
- Control input „Error Release“ for PNP signals [10 ... 30 VDC]
- Input frequency up to 400 kHz
- Pulse output with format A, /A, B, /B, Z, /Z [RS422]
- Pulse output with format A, B, 90° [HTL]
Frequency multiplier with frequency-accurate and pulse-consistent modulation.
- Pulse input with format A, B, Z [HTL single ended, TTL single ended] or
A, /A, B, /B, Z, /Z [RS422, HTL differential] - 4 control inputs for PNP signals [10 ... 30 VDC]
- Input and output frequency up to 1 MHz
- 3 incremental outputs with format A, /A, B, /B, Z, /Z, Push-Pull, [8 … 29 VDC]
With the use of BY701 firmware, the MC700 controller provides excellent solutions with all kind of multi-axes synchronizing applications. Numerous possibilities for control of relative phase, position, index and print mark evaluation are available.
In combination with the application firmware FS701, the universal MC700 hardware allows high-precision processing in machine applications such as "flying saws", "flying shears" and similar applications.
By using this application firmware, the MC800 controller is equipped for motion control tasks with typical “on-the-fly-processing” machines (e. g. sawing, cutting, punching, drilling, etc.).
Compared to the FS701 firmware, a significantly higher dynamic is achieved by using the combination FS801 firmware with MC800. In addition, processing to various sensor systems and fieldbus architectures is possible.
Compact and low priced Controller for machining "on the fly"
- 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 300 kHz
- 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
- 1 scalable 14 bit analog output (±10 V or 0/4 … 20 mA)
Performance as FS340, but with front-end cutting length specification and 4 output relays.
With firmware CT803, the new universal Motion-Controller MC800 with an integrated tandem drive-controller, flexible input configuration for sensors and adaptive interface structure is suitable for rotating processes.
Rotary cutters and other rotary applications require high dynamics, precise cuts and short position control cycles. These requirements will be complied by using the CT703 firmware and the MC700 motion controller.
Typical applications are intermittent or rotary operations like cutting, perforating,
printing, sealing, adhesion, applying, labeling and many more.
Easy control for rotating pressure, punching and sealing rollers. Short position control and precise cuts, even during speed changes.
- 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 300 kHz
- 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
- 1 scalable 14 bit analog output (±10 V or 0/4 … 20 mA)
Performance as CT340, but additionally with 4 relays outputs and cutting length adjustable by thumbwheel switch on front.
The firmware CT701, in combination with the controller MC700 offers a maximum processing performance with guillotine or eccentric shears in cut-to-length-lines.
Interface for motrona MC800 motion controller.
Interface for motrona Motion Controller MC800.
Due to highly dynamic motion profiles, the combination of firmware TB701 and MC700 controller works very precisely and is optimized for tubular bag packing machines (e.g.“pillow packaging”).
In combination with the motrona controller MC700, the firmware WR701 is suitable to implement all combinations of drives with rewinder, uncoiler, line drive, web tension control and transverse routing.
For numerous applications in the fields of printing, punching and labeling, motrona has developed corresponding firmware, which can be used in combination with the MC700 hardware. Thus, we are able to offer ready and tested solutions for a variety of machine applications.
Please do not hesitate to contact us - our engineers will be pleased to advise you.
Interface for motrona Motion Controller MC800.
1 axis positioning controller with extremely short control loop, analog output and 4 transistor outputs. Very suitable for smaller machines.
- 2 pulse inputs with format A, B, 90° [HTL] or A, /A, B, /B [RS422]
- 4 control inputs for HTL / PNP / NPN / Namur signals [10 ... 30 VDC]
- Input frequency up to 300 kHz
- 4 fast transistor outputs, push-pull, short-circuit-proof [5 … 30 VDC]
- 1 scalable 14 bit analog output (±10 V or 0/4 … 20 mA)
Performance as PS340, but additionally with 4 relay outputs and front-side thumbwheel switches for incremental positioning. Dimension 96 x 96 x 140 mm (3.78 x 3.78 x 5.51").