Signal Converters SSI Encoder to analogue - serial RS232 / RS485
SSI Encoder to parallel - seriell RS232
and SSI >>> optical fiber >>> SSI
|
|
* = instant stock availability
|
IV251*: Converter from SSI to Analogue (Voltage / Current) and to Serial RS232 / RS485
|
|
- SSI Signal converter suitable for use with all SSI type sensors and absolute encoders from 9 to 25 bits, either with Master mode or with Slave mode
- Analogue outputs +/- 10V, 0-20 mA or 4-20 mA, proportional to the encoder position
- RS 232 and RS 485 serial interface for readout of the actual encoder position
- Easy to set up by simple TEACH procedure, or by PC
(for operator software see SUPPORT)
- Free scaling, programmable linearization curves, bit blanking functions etc.
- Power units for 115/230 VA supply: see accessories
|
|
|
|
IP251*: Converter from SSI to Parallel (BCD, Binary, Gray) and SSI to Serial RS 232
|
|
- SSI Signal converter suitable to convert SSI data from an absolute encoder or sensor to parallel data, either with Master or Slave operation
- Also suitable for conversion of serial RS232 data to a parallel data format
- 25 bits parallel outputs, push-pull and short-circuit-proof, programmable output codes: Binary, Gray or BCD
- RS232 serial link for readout of sensor data
- Multiple facilities for scaling and linearization of parallel output data
- Easy to set up by DIL switches or by PC (operator software: see SUPPORT)
- Power units for 115/230 VAC supply: see accessories
|
|
|
|
PR210*: Converter from Parallel Data (BCD, Binary, Gray) to Serial Data (RS 232, RS485)
|
|
- Parallel data input (5 decades BCD or 20 bit binary or Gray)
- Serial RS232 / RS485 interface for readout of the parallel data
by means of a PC or PLC or other controls
- This converter is ideal for combinations with other motrona units in order to accomplish display of parallel data or conversion to other
formats like analogue or PROFIBUS etc.
- Some typical examples of combinations are shown under
“Combinations with Converters”
|
|
Please note that also some of our SSI Indicator Units are suitable for conversion
from SSI to analogue and from SSI to serial (see “SSI Indicators”)
|
|
|
LW 217/218*: Innovative optical fiber modules for a robust transmission
of SSI encoder or sensor signals
|
|
- The optical fibre modules LW217 and LW218 are forming together a transmission system for data transmission of SSI signals by means of optical
fibres.
- Safe and reliably transmission of signals, up to a distance of 1500m
- The optical fibre cable can be routed through explosive areas as well
- Resistant against extremely strong electromagnetic fields
- For use with all encoders and sensors equipped Synchronous Serial Interface (SSI)
- Adjustable maximum SSI resolution of 13 bit or 25 bit
- Maximum clock frequency 500 kHz
- Power supply either 5 VDC or 10-30 VDC
- Compact DIN rail mounting
- Glass fibre cables are available ready assembled
more optical fiber modules for incremental encoder or sensor signals (see LW215/216)
|
|